Skip to main content

Form library · Facilities and maintenance

Solar panel maintenance checklist

For people maintaining solar installations within an authorised scope. Record equipment and work, array and access and condition and performance. Try the form below, see every question or open a completed example.

Ready to use from the form library, and every question is yours to edit. Try it for a small trial fee, cancel any time.

Try it on your phone

Try it on this phone

Fill in the solar panel maintenance on your phone now

See how the solar panel maintenance looks on your phone

Scan the code with your phone camera. It opens the real form, no sign-up needed.

Open the live example and fill it in, just as your team would on site. No sign-up needed.

See it on this phone

Every question is editable. Add this form to your account, then change the wording, add or remove questions and options, and make it fit your own jobs.

Or start your trial with this form ready →

One email, and we won't add you to a mailing list.

What safety information matters for solar PV maintenance?

Government solar PV fire research identifies risks associated with PV systems, while HSE requires suitable electrical maintenance arrangements. Use competent people, system documentation and a safe method for the actual installation.

Last updated . Facts checked by the SiteSurvey team on 6 October 2026 against Government research on fire incidents involving solar panels and HSE maintaining electrical equipment safety.

Built for maintaining a solar array

Walk the array with the form on a phone. Record each defect with its position, priority and photos, compare generation with what was expected, and let the form count the urgent defects and the actions still open.

A defect on a phone: priority Repair soon and position on site Row 3, middle, followed by GPS coordinates, with Mark again and View on map

Pin each defect on the array

Mark the position of each defect at the module. On a ground mount or a large roof, the repair team walks straight to the cracked module from the map link and grid reference. Mark current location works on web forms in any phone browser today, and the app version is on its way.

How GPS location works →
Generation 49800 kWh against 53000 kWh expected on a phone, worked out as 94 percent

Generation against expected

Enter the generation for the period and the figure you expected, from the design estimate or last year, and the form shows the percentage. Under 85% brings up a reminder to check shading, soiling and the inverters.

How calculated fields work →
Defects recorded 3 and urgent defects 1 on a phone, with a red reminder to record the isolation

Urgent defects counted

The form counts the defects recorded and the urgent ones, and an urgent defect brings up a reminder to record the isolation and who was told.

How calculated fields work →

Walk the rows on camera

Walk Cam records the rows with your spoken notes, so the condition of the whole array is kept with the maintenance record.

How Walk Cam works →

A completed solar maintenance record

The annual visit to a fictional farm's 55 kWp ground mount: a cracked module isolated on its string, bird fouling cleaned, brambles cut back from a row, and generation at 94% of the design estimate.

A ground-mounted solar panel with a spider web crack across the glass from an impact near one corner
Row 2, module 14 · cracked glass · string isolated
Brambles and tall weeds growing up in front of the bottom of a row of ground-mounted solar panels
Row 3 · brambles shading the bottom cells · cut back
The lower edge of a ground-mounted solar panel covered in bird droppings and dust
Row 2 · bird fouling · cleaned

Try the solar panel maintenance form live

Answer a few questions and watch it adapt. Your answers are not saved, and any photos you add are deleted within the hour.

Live form: Solar Panel MaintenanceOpen full screen ↗
Fill it in right here

This is the real form as your team would use it: questions appear as you answer, scores work themselves out and you can add photos and signatures. No sign-up needed. Or open a completed example to see every answer, photo and score filled in.

Want to see one filled in? See a completed solar panel maintenance report (PDF), made by SiteSurvey from a fictional site visit.

Walk Cam route · four guided clips

Record the solar panel maintenance on video

Show array identity, panel faces, frame edges and a final location view without touching electrical equipment.

Confirm array or row reference and permitted access route. Film a wide view before accessible panel faces and frame edges. Do not touch live equipment, walk on modules or access a roof without the required work-at-height controls.

See the footage in a report

A fictional six-page example with the four points, twelve stills from the clips, observations, follow-up actions and the limits of a visual record.

View the visual evidence (PDF) ↗ · Download the full sample report

Visual evidence page from the solar panel condition visual inspection sample report, with footage stills and observations

Phone video cannot measure output, insulation, hotspots, microcracks, earthing or electrical safety. It records visible appearance only and cannot replace O&M testing or a competent inspection. Example footage was generated in Google Flow and the observations are scripted; no real site is shown. Walk Cam works inside any form in the app. How Walk Cam works · All visual inspections

For teams

Using the solar panel maintenance template for client work?

Paper or a spreadsheet works for the odd job. When your team does this every week, SiteSurvey keeps every visit in one place and turns each one into a report you can send.

  • Everyone fills in the same form on their phone, with photos attached to the answer they belong to.
  • Each visit becomes a branded PDF report for the client, with no retyping.
  • Every site, visit and report is kept together in one account, not scattered across email and shared drives.

Fill it in on a phone or tablet

Your team completes the solar panel maintenance on site in the SiteSurvey app on iPhone, iPad and Android phones and tablets. The project name and address fill in for them, it works without signal, and it syncs when the device is back online with photos kept against the question they answer.

Customers and subcontractors do not need the app: send them a link and they can fill it in from any browser.

The Solar Panel Maintenance form in the SiteSurvey app on a tablet
The Solar Panel Maintenance form in the SiteSurvey app on a phone

Every question in the solar panel maintenance template

A solar PV maintenance record with array identification, safe access, visible module and cable condition, inverter information and specialist test references. 6 sections and 59 questions. Follow-up questions and guidance appear only when an answer calls for them, so the person on site never sees the ones that do not apply.

Make it your own: every question is editable

This is a starting point, not a fixed form. Once it is in your SiteSurvey account you can reword any question, add or remove questions, sections and answer options, and add your own logo, so it fits the way your team works and the jobs you do.

Details you only enter once

Add this form to a project in SiteSurvey and it fills in what the project already knows, so nobody on site retypes it and every form on the job uses the same names. Anything filled in can still be changed.

  • Project: the project name
  • Site or premises address: the site address, from the space or the project
  • Client or organisation: the project's customer
  • Manufacturer, model and serial number: the product's model

Record details and scope

  • ProjectShort answer

    Filled in from the project in SiteSurvey.

    Fills in from the project name
  • Site or premises addressShort answer
    Fills in from the site address, from the space or the project
  • Client or organisationShort answer
    Fills in from the project's customer
  • Record date*Date
  • Person completing the record*Short answer
  • Weather on siteAnswer
  • CheckThis is a maintenance evidence record, not electrical design or isolation instructions. PV circuits can remain energised in daylight; switching off an inverter is not proof that every circuit is dead.
  • CheckThe Electricity at Work Regulations 1989, regulation 4(2), require electrical systems to be maintained so far as reasonably practicable to prevent danger, and regulation 16 requires the people doing the work to be competent. Periodic verification and tests of grid-connected PV follow BS EN 62446-1 (documentation, commissioning tests and inspection), the IET Code of Practice for Grid-connected Solar Photovoltaic Systems and the system O&M manual. MCS MIS 3002 sets the installer handover, including the maintenance schedule. Use competent people, the system documents and a safe method for the actual installation.

Equipment and work

  • Solar PV system asset ID and location*Short answer
  • Manufacturer, model and serial number*Short answer
    Fills in from the product's model
  • Maintenance procedure and revision*Short answer
  • Technician and competence reference*Short answer
  • Planned work and exclusions*Notes
  • Safe isolation or permit reference*Short answer

Array and access

  • Array locations, module type and system capacityShort answer
  • Inverter identifiers and firmware or alarm referencesShort answer
  • Roof access, edge protection and access-plan reference*Short answer
  • Areas inaccessible or excluded from inspectionNotes

    Identify inaccessible areas and tests not performed. Keep a visual observation separate from an electrical or structural conclusion.

Condition and performance

  • Visible module damage and soiling recorded*Choose one
    • Acceptable
    • Action needed
    • Not checked
    • Not applicable
  • Action, limitation or reason not applicable*Notes
    Shown only when the answers above make it relevant
  • Mounting and roof interface observations recorded from safe access*Choose one
    • Acceptable
    • Action needed
    • Not checked
    • Not applicable
  • Action, limitation or reason not applicable*Notes
    Shown only when the answers above make it relevant
  • Visible cables, connectors and labels checked within authorised scope*Choose one
    • Acceptable
    • Action needed
    • Not checked
    • Not applicable
  • Action, limitation or reason not applicable*Notes
    Shown only when the answers above make it relevant
  • Inverter alarms and monitoring data reviewed*Choose one
    • Acceptable
    • Action needed
    • Not checked
    • Not applicable
  • Action, limitation or reason not applicable*Notes
    Shown only when the answers above make it relevant
  • Checks needing actionWorked out by the form
  • Are there defects to record?Yes or No
  • Defects
    Repeat for each defect. Each one asks:
    Shown when “Are there defects to record?” is Yes
    • Array, row and moduleShort answer
    • DefectChoose one
      • Cracked or broken glass
      • Hot spot, burn mark or discolouration
      • Heavy soiling or bird fouling
      • Loose or damaged mounting
      • Damaged cable or connector
      • Vegetation or new shading
      • Pest or bird nesting under the array
      • Other
    • What you foundShort answer
    • PriorityChoose one
      • Urgent: isolate or make safe
      • Repair soon
      • Monitor
    • Position on siteShort answer

      Mark current location at the module. Useful on ground mounts and large roofs.

    • PhotosPhotos
  • Defects recordedWorked out by the form
    Shown when “Are there defects to record?” is Yes
  • Urgent defectsWorked out by the form
    Shown when “Are there defects to record?” is Yes
  • WarningAn urgent defect is recorded. Record the isolation or restriction and who was told on the handback page.
    Shown only when the answers above make it relevant
  • Generation period and comparison basisShort answer
  • Generation for the period (kWh)Number
  • Expected for the same period (kWh)Number

    From the design estimate, the same period last year or the monitoring platform's expected yield.

  • Generation against expected (%)Worked out by the form
    Shown only when the answers above make it relevant
  • CheckGeneration is under 85% of expected. Check shading, soiling, inverter alarms and string outputs before putting it down to the weather.
    Shown only when the answers above make it relevant
  • Specialist electrical test report referencesNotes
  • Walk Cam: solar panel condition visual inspectionWalk Cam video with voice-to-text

    Optional. Film the four guided points on the SiteSurvey app; each clip keeps its spoken note.

Work and handback

  • Work performed and parts usedNotes
  • Post-work tests and evidenceNotes
  • Equipment handback*Choose one
    • Available within recorded limits
    • Restricted use
    • Out of service
  • Restrictions, isolation and person informed*Notes
    Shown only when the answers above make it relevant
  • Condition and work evidence photosPhotos
  • Next maintenance dueDate

    Set from the O&M manual or the maintenance contract.

  • Days to the next maintenanceWorked out by the form
    Shown when “Record date” is answered and “Next maintenance due” is answered
  • CheckThe next due date is before the date of this visit. Check the date.
    Shown only when the answers above make it relevant

Actions and review

  • Are further actions required?*Choose one
    • Yes
    • No
  • Further action
    Repeat for each further action. Each one asks:
    Shown when “Are further actions required?” is “Yes”
    • Action and evidence reference*Notes
    • Person responsible*Short answer
    • Target dateDate
    • Action status*Choose one
      • Open
      • In progress
      • Completed
    • Completion evidence*Notes
      Shown when “Action status” is “Completed”
  • Actions still openWorked out by the form
    Shown when “Are further actions required?” is “Yes”
  • Outstanding limitations and information to pass onNotes
  • Record status*Choose one
    • Ready for review
    • Further work needed
    • Work or use stopped
  • Reviewed byShort answer
  • Review dateDate
  • Author signature*Signature
  • CheckSigning records the information entered. It does not itself certify legal compliance, remove a limitation or authorise unsafe work.

Scope and responsibility

This is a maintenance evidence record, not electrical design or isolation instructions. PV circuits can remain energised in daylight; switching off an inverter is not proof that every circuit is dead.

What a useful entry looks like

Areas inaccessible or excluded from inspection

Identify inaccessible areas and tests not performed. Keep a visual observation separate from an electrical or structural conclusion.

North roof-edge modules were not accessed. Observations were made from the agreed position; electrical testing is recorded only where separately authorised.

Fictional example of record wording. Use the actual evidence and approved arrangements for your job; this is not a completed report or an instruction to carry out the work.

See it filled in

A completed solar panel maintenance report, made by SiteSurvey from a fictional site visit: every answer, the photos, the guidance that applied and the sign-off, ready to send as a PDF.

See completed form (PDF) ↗

Solar Panel Maintenance FAQs

How should I record “Areas inaccessible or excluded from inspection”?

Identify inaccessible areas and tests not performed. Keep a visual observation separate from an electrical or structural conclusion.

Does switching off the inverter isolate the array?

Do not assume so. Follow the installation-specific safe working method and competent electrical advice.

Can I attach thermal or electrical results?

Record the report reference and supporting images, with test conditions and limitations. The template does not interpret specialist test results.

Does this replace a roof inspection?

No. Record visible concerns and refer roof integrity or structural questions for appropriate assessment.

What are the limits of this template?

This is a maintenance evidence record, not electrical design or isolation instructions. PV circuits can remain energised in daylight; switching off an inverter is not proof that every circuit is dead.

Can I complete this form on site and share the record?

In the SiteSurvey app the form works offline, with photos and signatures recorded against the questions. Share the completed record as a PDF or a link. Dates and action owners are recorded fields; this form does not send reminders or update other systems.

Related

Use this solar panel maintenance form with your team

Add it from the form library in one click, change any question, and every completed form becomes a branded PDF report.