Skip to main content

Form library · Facilities and maintenance

Energy audit checklist

For people reviewing building energy use and improvement options. Enter the year's electricity and gas, unit rates and floor area, and the form works out the energy cost and kWh per square metre. Add each opportunity with its estimated saving and cost, and it prices the saving, works out the simple payback, measures a door or window from a photo and adds up the savings as a share of the energy used. Try the form below, see every question or open a completed example.

Ready to use from the form library, and every question is yours to edit. Try it for a small trial fee, cancel any time.

Try it on your phone

Try it on this phone

Fill in the premises energy audit on your phone now

See how the premises energy audit looks on your phone

Scan the code with your phone camera. It opens the real form, no sign-up needed.

Open the live example and fill it in, just as your team would on site. No sign-up needed.

See it on this phone

Every question is editable. Add this form to your account, then change the wording, add or remove questions and options, and make it fit your own jobs.

Or start your trial with this form ready →

One email, and we won't add you to a mailing list.

Is this an ESOS assessment?

No. ESOS has defined qualification and compliance requirements, including the assessment of energy use and identification of saving opportunities. GOV.UK also provides guidance on implementing opportunities. This walk-through can collect supporting observations, but it does not establish ESOS compliance or replace the required assessment process.

Last updated . Facts checked by the SiteSurvey team on 6 October 2026 against GOV.UK ESOS qualification and compliance and GOV.UK implementing energy saving opportunities.

Built for energy walk-throughs of a building

Enter the year's electricity and gas with the unit rates and floor area, then add each opportunity as you walk round. The form works out the energy cost, kWh per square metre, each saving in pounds and its simple payback, measures a door or window from a photo, and adds up the savings as a share of the energy used. The figures are estimates for deciding what to look at next, not an ESOS assessment, an EPC or a guarantee of savings.

Energy cost at these rates worked out as £76,963, and energy use per square metre as 216.3 kWh/m² from a floor area of 2,450 m²

Consumption, cost and kWh per m²

Enter the electricity and gas used in the period, the unit rates and the floor area. The form works out the total, the cost at those rates and the energy use per square metre, so buildings can be compared.

How calculated fields work →
An opportunity with an estimated saving of 6,000 kWh a year, worked out as £372 a year, a cost of £4,200 and a simple payback of 11.3 years

Each saving in pounds, with payback

For each opportunity, enter the estimated kWh saved and the cost to put it in. The form prices the saving at the unit rate for that fuel and works out the simple payback in years.

How calculated fields work →
Width of the area filled in as 1.76 m with the measuring photo as a thumbnail, and the area worked out from the width and height

Measure a door or window from a photo

For a fabric measure, photograph the opening square on with a door in shot, tap the door's height, then the width and height of the opening. The form works out the area. It is an estimate: a supplier measures with a tape. It works on web forms in any phone browser today, and the app version is on its way.

How measuring from a photo works →
Totals worked out as 5 opportunities, 51,500 kWh a year, 10% of the energy used, about £8,225 a year and £17,850 to put in place, with a note that these are estimates

Savings added up

The form adds up the savings, their share of the energy used, the cost saving and the cost to put them in. A note says they are walk-through estimates that can overlap, so they are checked before they go into a business case.

How calculated fields work →

A completed premises energy audit

Four floors of fictional serviced offices: an air handling unit running at weekends, heating and cooling fighting each other, lights left on, and a loading bay shutter left open under a gas heater, measured at about 1.76 by 2.87 m from a photo. Open it as a filled-in form, or switch to a blank copy and try it yourself.

A loading bay with the roller shutter open and a personnel door beside it, marked up to give a width of about 1.76 m from the 1.98 m door
Loading bay shutter · about 1.76 m wide, 2.87 m high
An empty open-plan office in the evening with all the ceiling lights on
Lights on in empty rooms at 18:30 · 14,000 kWh a year
Air conditioning condensers on a flat roof
Roof condensers · dead band with the heating
Walk Cam recording the roof condensers

Try the premises energy audit form live

Answer a few questions and watch it adapt. Your answers are not saved, and any photos you add are deleted within the hour.

Live form: Premises Energy AuditOpen full screen ↗
Fill it in right here

This is the real form as your team would use it: questions appear as you answer, scores work themselves out and you can add photos and signatures. No sign-up needed. Or open a completed example to see every answer, photo and score filled in.

Want to see one filled in? See a completed premises energy audit report (PDF), made by SiteSurvey from a fictional site visit.

Fill it in on a phone or tablet

Your team completes the premises energy audit on site in the SiteSurvey app on iPhone, iPad and Android phones and tablets. The project name and address fill in for them, it works without signal, and it syncs when the device is back online with photos kept against the question they answer.

Customers and subcontractors do not need the app: send them a link and they can fill it in from any browser.

The Premises Energy Audit form in the SiteSurvey app on a tablet
The Premises Energy Audit form in the SiteSurvey app on a phone

Every question in the premises energy audit template

A premises energy walk-through with consumption evidence, occupancy, plant and controls, observed opportunities, estimates and follow-up ownership. 5 sections and 54 questions. Follow-up questions and guidance appear only when an answer calls for them, so the person on site never sees the ones that do not apply.

Make it your own: every question is editable

This is a starting point, not a fixed form. Once it is in your SiteSurvey account you can reword any question, add or remove questions, sections and answer options, and add your own logo, so it fits the way your team works and the jobs you do.

Details you only enter once

Add this form to a project in SiteSurvey and it fills in what the project already knows, so nobody on site retypes it and every form on the job uses the same names. Anything filled in can still be changed.

  • Project: the project name
  • Site or premises address: the site address, from the space or the project
  • Client or organisation: the project's customer

Record details and scope

  • ProjectShort answer

    Filled in from the project in SiteSurvey.

    Fills in from the project name
  • Site or premises addressShort answer
    Fills in from the site address, from the space or the project
  • Client or organisationShort answer
    Fills in from the project's customer
  • Record date*Date
  • Person completing the record*Short answer
  • CheckThis records observations and supporting data. It is not an EPC, DEC, ESOS compliance report or a guarantee of savings.
  • CheckThe Energy Savings Opportunity Scheme Regulations 2014 (ESOS), as amended in 2023, set qualification and compliance requirements for large undertakings, including an assessment of energy use and identification of saving opportunities, overseen by a lead assessor. GOV.UK also provides guidance on implementing opportunities. This walk-through can collect supporting observations, but it does not establish ESOS compliance or replace the required assessment process.

Scope and consumption

  • Walk Cam: energy walk-roundWalk Cam video with voice-to-text

    Optional. Film a guided walk-through on the SiteSurvey app.

  • Buildings and systems included*Notes
  • Consumption-data periodShort answer
  • Meter, bill or monitoring data references and units*Notes
  • Electricity used in the period (kWh)Number

    From the meter data or bills for the period above. Use 12 months so the savings below compare with a year.

  • Gas used in the period (kWh)Number
  • Other fuels in the period (kWh)Number

    Oil, LPG or biomass converted to kWh, if any.

  • Total energy used (kWh)Worked out by the form
    Shown only when the answers above make it relevant
  • Electricity unit rate (p/kWh)Number

    From the current contract or bill.

  • Gas unit rate (p/kWh)Number
  • Energy cost at these rates (£)Worked out by the form

    Unit rates only: standing charges, levies and VAT are not included.

    Shown only when the answers above make it relevant
  • Gross internal floor area (m²)Number

    From the plans or the lease.

  • Energy use per square metre (kWh/m²)Worked out by the form
    Shown only when the answers above make it relevant
  • Occupancy and operating hoursNotes
  • Missing data and seasonal limitationsNotes

Systems observed

  • System or area
    Repeat for each system or area. Each one asks:
    • System, area and asset reference*Short answer
    • Operating hours, settings and observed useNotes
    • Potential improvement and supporting evidence*Notes
    • The saving would be inChoose one
      • Electricity
      • Gas
      • Other
    • Estimated saving (kWh a year)Number
    • Estimated cost saving (£ a year)Worked out by the form
      Shown only when the answers above make it relevant
    • Estimated cost to put in place (£)Number
    • Simple payback (years)Worked out by the form
      Shown only when the answers above make it relevant
    • Width of the area, for a fabric measure (m)Number

      Optional, for a door, window, roof light or wall. Photograph it square on with a door or a known length in shot and use Measure from photo. An estimate: measure with a tape for a quote.

    • Height of the area (m)Number
    • Area (m²)Worked out by the form
      Shown only when the answers above make it relevant
    • How the saving was estimated (calculation reference)Short answer
    • Assumptions, dependencies and need for specialist assessmentNotes
    • Supporting photosPhotos
  • Opportunities recordedWorked out by the form
  • Estimated saving (kWh a year)Worked out by the form
  • Of the energy used (%)Worked out by the form
    Shown only when the answers above make it relevant
  • Estimated cost saving (£ a year)Worked out by the form
  • Estimated cost to put in place (£)Worked out by the form
  • CheckThese totals add up the estimates entered above. They are walk-through estimates at today's unit rates, not a guarantee of savings, and measures can overlap: check them before adding them to a business case.
    Shown only when the answers above make it relevant

Implementation review

  • Opportunities selected for further assessmentNotes
  • Comfort, safety, maintenance and operational constraintsNotes
  • Baseline and proposed verification methodShort answer

    Define the comparison period and changes in occupancy or operation. An estimated saving needs its assumptions and verification method.

  • Person coordinating follow-upShort answer

Actions and review

  • Are further actions required?*Choose one
    • Yes
    • No
  • Further action
    Repeat for each further action. Each one asks:
    Shown when “Are further actions required?” is “Yes”
    • Action and evidence reference*Notes
    • Person responsible*Short answer
    • Target dateDate
    • Action status*Choose one
      • Open
      • In progress
      • Completed
    • Completion evidence*Notes
      Shown when “Action status” is “Completed”
  • Outstanding limitations and information to pass onNotes
  • Record status*Choose one
    • Ready for review
    • Further work needed
    • Work or use stopped
  • Reviewed byShort answer
  • Review dateDate
  • Author signature*Signature
  • CheckSigning records the information entered. It does not itself certify legal compliance, remove a limitation or authorise unsafe work.

Scope and responsibility

This records observations and supporting data. It is not an EPC, DEC, ESOS compliance report or a guarantee of savings.

What a useful entry looks like

Baseline and proposed verification method

Define the comparison period and changes in occupancy or operation. An estimated saving needs its assumptions and verification method.

Baseline uses the previous 12 monthly electricity bills. The additional evening shift introduced in September must be considered when comparing results.

Fictional example of record wording. Use the actual evidence and approved arrangements for your job; this is not a completed report or an instruction to carry out the work.

See it filled in

A completed premises energy audit report, made by SiteSurvey from a fictional site visit: every answer, the photos, the guidance that applied and the sign-off, ready to send as a PDF.

See completed form (PDF) ↗

Premises Energy Audit FAQs

How should I record “Baseline and proposed verification method”?

Define the comparison period and changes in occupancy or operation. An estimated saving needs its assumptions and verification method.

Does the form calculate savings?

No. Enter an estimate only with its units, assumptions and calculation reference. The form does not validate the estimate.

Can I use it without a year of meter data?

You can record observations, but state the period and missing information. Do not present a short visit as a complete annual energy assessment.

Does it cover operational constraints?

Yes. Record comfort, safety, maintenance and operational requirements before deciding whether an opportunity is suitable.

What are the limits of this template?

This records observations and supporting data. It is not an EPC, DEC, ESOS compliance report or a guarantee of savings.

Can I complete this form on site and share the record?

In the SiteSurvey app the form works offline, with photos and signatures recorded against the questions. Share the completed record as a PDF or a link. Dates and action owners are recorded fields; this form does not send reminders or update other systems.

Related

Use this premises energy audit form with your team

Add it from the form library in one click, change any question, and every completed form becomes a branded PDF report.

Start your trial →