Skip to main content

Form library · Facilities and maintenance

Asbestos register and management plan template

For dutyholders and people re-inspecting asbestos materials and reviewing the register. Each material gets its location, evidence status, extent, condition and controls. Enter the four scores from the survey and the form works out the HSG264 material assessment score and band, and counts the known, presumed and high scoring materials. Outside materials can be pinned by GPS, and the extent can be measured from a photo without touching the material. Try the form below, see every question or open a completed example.

Ready to use from the form library, and every question is yours to edit. Try it for a small trial fee, cancel any time.

Try it on your phone

Try it on this phone

Fill in the asbestos register and management review on your phone now

See how the asbestos register and management review looks on your phone

Scan the code with your phone camera. It opens the real form, no sign-up needed.

Open the live example and fill it in, just as your team would on site. No sign-up needed.

See it on this phone

Every question is editable. Add this form to your account, then change the wording, add or remove questions and options, and make it fit your own jobs.

Or start your trial with this form ready →

One email, and we won't add you to a mailing list.

What is the purpose of an asbestos register?

HSE describes the register as a live record of known and presumed asbestos-containing materials, informed by survey evidence and used as part of the management plan. The plan records how risks will be managed and how information is given to people who may disturb materials. Confirm that the duty to manage applies to the premises.

Last updated . Facts checked by the SiteSurvey team on 6 October 2026 against HSE asbestos registers and risk assessment, HSE writing and monitoring an asbestos management plan and HSE HSG264 Asbestos: The survey guide (material assessment, appendix 4).

Built for re-inspecting asbestos materials on site

Take the register round the building on a phone. For each known or presumed material, record what you see without touching it, copy the survey's scores and let the form work out the material assessment, and count the materials and actions across the register. It is a management record, not a survey.

Damage, surface treatment and asbestos type scores for pipe lagging on a phone, with Material assessment score 10 and Potential to release fibres High, worked out

Material score worked out

Copy the four scores from the survey report: product type, damage, surface treatment and asbestos type. The form adds them up as in HSE guidance HSG264 and shows the band, from very low to high potential to release fibres.

How calculated fields work →
Register counts worked out on a phone: known asbestos 1, presumed asbestos 2, information unresolved 0, materials scoring 10 or more 1

The register counted

The form counts the known, presumed and unresolved materials, those scoring 10 or more and 7 to 9, and the actions still open, so the review starts from the numbers.

How calculated fields work →
Extent length 5.9 m with a measuring photo thumbnail and width 5.5 m for a garage roof, with the area worked out below

Extent without touching it

Measure the extent from a photo taken where you stand, with a person, a door or an A4 sheet in the same plane. Nothing is touched or disturbed, and the area is worked out for you. It works on web forms in any phone browser today, and the app version is on its way.

How measuring from a photo works →
Position on site for a garage block filled in by GPS, with Mark again and View on map, above the evidence status Presumed asbestos

Pin materials outside

For a cement sheet roof, a garage block or a boiler house on a large site, mark the material's position, so a contractor finds the right one. Mark current location works on web forms in any phone browser today, and the app version is on its way.

How GPS location works →

A completed asbestos register review

The annual review at a fictional community centre: insulating board in the boiler room, damaged pipe lagging scoring 10 with a licensed contractor booked, and a presumed cement sheet garage roof pinned by GPS. Open it as a filled-in form, or switch to a blank copy and try it yourself.

Old painted pipe lagging cracked and broken at a bend in a boiler room, wrapped in red and white barrier tape
A04 · pipe lagging, presumed · score 10, high
A brick garage block with a corrugated cement sheet roof measured from a photo at about 5.9 m along the eaves against a person 1.83 m tall
A07 · garage roof sheets, presumed · about 5.9 m
Ceiling panels above a boiler with an asbestos warning label
A03 · insulating board ceiling, known · score 6, low
Filming the damaged lagging from outside the barrier tape

Try the asbestos register and management review form live

Answer a few questions and watch it adapt. Your answers are not saved, and any photos you add are deleted within the hour.

Live form: Asbestos Register and Management ReviewOpen full screen ↗
Fill it in right here

This is the real form as your team would use it: questions appear as you answer, scores work themselves out and you can add photos and signatures. No sign-up needed. Or open a completed example to see every answer, photo and score filled in.

Want to see one filled in? See a completed asbestos register and management review report (PDF), made by SiteSurvey from a fictional site visit.

For teams

Using the asbestos register and management review template for client work?

Paper or a spreadsheet works for the odd job. When your team does this every week, SiteSurvey keeps every visit in one place and turns each one into a report you can send.

  • Everyone fills in the same form on their phone, with photos attached to the answer they belong to.
  • Each visit becomes a branded PDF report for the client, with no retyping.
  • Every site, visit and report is kept together in one account, not scattered across email and shared drives.

Fill it in on a phone or tablet

Your team completes the asbestos register and management review on site in the SiteSurvey app on iPhone, iPad and Android phones and tablets. The project name and address fill in for them, it works without signal, and it syncs when the device is back online with photos kept against the question they answer.

Customers and subcontractors do not need the app: send them a link and they can fill it in from any browser.

The Asbestos Register and Management Review form in the SiteSurvey app on a tablet
The Asbestos Register and Management Review form in the SiteSurvey app on a phone

Every question in the asbestos register and management review template

An asbestos management record linking known or presumed materials to survey evidence, condition observations, controls, communication and review actions. 5 sections and 51 questions. Follow-up questions and guidance appear only when an answer calls for them, so the person on site never sees the ones that do not apply.

Make it your own: every question is editable

This is a starting point, not a fixed form. Once it is in your SiteSurvey account you can reword any question, add or remove questions, sections and answer options, and add your own logo, so it fits the way your team works and the jobs you do.

Details you only enter once

Add this form to a project in SiteSurvey and it fills in what the project already knows, so nobody on site retypes it and every form on the job uses the same names. Anything filled in can still be changed.

  • Project: the project name
  • Site or premises address: the site address, from the space or the project
  • Client or organisation: the project's customer

Record details and scope

  • ProjectShort answer

    Filled in from the project in SiteSurvey.

    Fills in from the project name
  • Site or premises addressShort answer
    Fills in from the site address, from the space or the project
  • Client or organisationShort answer
    Fills in from the project's customer
  • Record date*Date
  • Person completing the record*Short answer
  • CheckThis is a management record, not an asbestos survey, sampling method or clearance certificate. An uninspected area must not be recorded as asbestos-free.
  • CheckRegulation 4 of the Control of Asbestos Regulations 2012 (the duty to manage) requires the dutyholder for non-domestic premises to find out whether asbestos is present, presume materials contain asbestos unless there is strong evidence they do not, keep an up to date written record of their location and condition, assess the risk, prepare and act on a plan to manage it, review and monitor the plan at regular intervals, and give the information to anyone liable to disturb the materials. HSE guidance HSG227 (A comprehensive guide to managing asbestos in premises) covers the management plan and HSG264 (Asbestos: the survey guide) covers surveys and the material assessment. The register is a live record informed by survey evidence. Confirm that the duty to manage applies to the premises.

Evidence and dutyholder

  • Dutyholder or management contact*Short answer
  • Survey report reference, date and surveyor*Short answer
  • Survey scope and areas not accessed*Notes
  • Management plan reference and revisionShort answer

Materials register

  • Material or location
    Repeat for each material. Each one asks:
    • Exact location and item reference*Short answer
    • Position on siteShort answer

      For materials outside or on a large site, such as a cement sheet roof or a boiler house: mark it from where you stand.

    • Evidence status*Choose one
      • Known asbestos
      • Presumed asbestos
      • Information unresolved
    • Survey or sample result referenceShort answer
    • Material description, extent and accessibilityNotes
    • Extent: length (m)Number

      Measure from a photo taken from where you stand, with a door or an A4 sheet in the same plane. Never touch or disturb the material to measure it.

    • Extent: width or height (m)Number
    • Extent: area (m²)Worked out by the form
      Shown only when the answers above make it relevant
    • Condition observation and observation dateNotes
    • GuidanceMaterial assessment. Copy the four scores from the survey report. They follow the material assessment in HSE guidance HSG264: product type, extent of damage, surface treatment and asbestos type. The assessment is the surveyor's; this register does not replace it, and it leaves out the priority assessment, which looks at how the area is used.
      Shown only when the answers above make it relevant
    • Product type scoreChoose one
      • 1: reinforced composite, such as asbestos cement, vinyl tiles, textured coating
      • 2: insulating board, millboard, textiles, gaskets, rope, paper
      • 3: pipe or boiler lagging, sprayed coating, loose fill
      Shown only when the answers above make it relevant
    • Extent of damage scoreChoose one
      • 0: good condition
      • 1: low damage, scratches or broken edges
      • 2: medium damage, some loose fibres
      • 3: high damage or delamination, visible debris
      Shown only when the answers above make it relevant
    • Surface treatment scoreChoose one
      • 0: composite, such as reinforced plastics, resins, vinyl tiles
      • 1: enclosed sprays and lagging, sealed board, cement sheet
      • 2: unsealed board, or encapsulated lagging and sprays
      • 3: unsealed lagging and sprays
      Shown only when the answers above make it relevant
    • Asbestos type scoreChoose one

      Presumed and not sampled: score 3 unless the survey says otherwise.

      • 1: chrysotile
      • 2: amphibole other than crocidolite, such as amosite
      • 3: crocidolite, or presumed and not sampled
      Shown only when the answers above make it relevant
    • Material assessment scoreWorked out by the form
      Shown only when the answers above make it relevant
    • Potential to release fibresWorked out by the form
      Shown only when the answers above make it relevant
    • Management controls and restrictions*Notes
    • Competent person responsible for reviewShort answer
    • Photos of the materialPhotos

      Use existing evidence or photos taken safely. Do not disturb the material.

  • Known asbestosWorked out by the form
  • Presumed asbestosWorked out by the form
  • Information unresolvedWorked out by the form
  • Materials scoring 10 or moreWorked out by the form
  • Materials scoring 7 to 9Worked out by the form
  • CheckA material with a high score needs prompt management action: the controls and actions should say what is being done, by whom and when.
    Shown only when the answers above make it relevant

Management review

  • Changes in condition, occupancy or planned workNotes
  • How affected workers and contractors receive current information*Notes
  • Controls for areas with missing or incomplete informationNotes

    Identify uninspected areas and the limitation in the evidence. Do not treat an inaccessible area as confirmed free of asbestos.

  • Planned management review dateDate
  • Days to planned reviewWorked out by the form
    Shown when “Record date” is answered and “Planned management review date” is answered
  • CheckThe next due date is before the date of this record. Check the date entered.
    Shown only when the answers above make it relevant
  • Reason for review timing and responsible personNotes

Actions and review

  • Are further actions required?*Choose one
    • Yes
    • No
  • Further action
    Repeat for each further action. Each one asks:
    Shown when “Are further actions required?” is “Yes”
    • Action and evidence reference*Notes
    • PriorityChoose one
      • Urgent
      • High
      • Medium
      • Low
    • Person responsible*Short answer
    • Target dateDate
    • Action status*Choose one
      • Open
      • In progress
      • Completed
    • Completion evidence*Notes
      Shown when “Action status” is “Completed”
  • Actions still openWorked out by the form
    Shown when “Are further actions required?” is “Yes”
  • Outstanding limitations and information to pass onNotes
  • Record status*Choose one
    • Ready for review
    • Further work needed
    • Work or use stopped
  • Reviewed byShort answer
  • Review dateDate
  • Author signature*Signature
  • CheckSigning records the information entered. It does not itself certify legal compliance, remove a limitation or authorise unsafe work.

Scope and responsibility

This is a management record, not an asbestos survey, sampling method or clearance certificate. An uninspected area must not be recorded as asbestos-free.

What a useful entry looks like

Controls for areas with missing or incomplete information

Identify uninspected areas and the limitation in the evidence. Do not treat an inaccessible area as confirmed free of asbestos.

Ceiling void above store S2 was not accessed in survey AS-07. The limitation remains on the register and is flagged for planned work.

Fictional example of record wording. Use the actual evidence and approved arrangements for your job; this is not a completed report or an instruction to carry out the work.

See it filled in

A completed asbestos register and management review report, made by SiteSurvey from a fictional site visit: every answer, the photos, the guidance that applied and the sign-off, ready to send as a PDF.

See completed form (PDF) ↗

Asbestos Register and Management Review FAQs

Can I mark a room asbestos-free after looking at it?

No. This form does not establish absence of asbestos. Record survey evidence, assumptions and limitations, including inaccessible areas.

Is the register a complete management plan?

It is part of the management record. Controls, responsibilities, communication and review arrangements still need to be established and implemented.

How does the form score each material?

Copy the four scores from the survey report: product type, extent of damage, surface treatment and asbestos type. The form adds them up to the material assessment score in HSE guidance HSG264, from 2 to 12, and shows the band: 10 or more high, 7 to 9 medium, 5 to 6 low, 4 or less very low potential to release fibres. HSG264 scores presumed materials as crocidolite unless there is strong evidence otherwise. The score is the surveyor's; the form does not include the priority assessment, which also looks at how the area is used.

Can I use it for a periodic asbestos inspection?

Yes, as a re-inspection record of materials already on the register: record the condition you see, the date, photos and any change in controls. Measure the extent from a photo taken where you stand, with a door or an A4 sheet in the same plane, so nothing is touched (web forms today, the app version is coming). It is not an asbestos survey and does not find materials that are not already known or presumed.

What are the limits of this template?

This is a management record, not an asbestos survey, sampling method or clearance certificate. An uninspected area must not be recorded as asbestos-free.

Can I complete this form on site and share the record?

In the SiteSurvey app the form works offline, with photos and signatures recorded against the questions. Share the completed record as a PDF or a link. Dates and action owners are recorded fields; this form does not send reminders or update other systems.

Related

Hazards this form covers

Who each hazard harms, what the law expects and the control measures to look for, in our hazard library.

Use this asbestos register and management review form with your team

Add it from the form library in one click, change any question, and every completed form becomes a branded PDF report.

Start your trial →