Skip to main content

Form library · Quality and compliance

Welding inspection checklist

For people recording welding inspection to agreed requirements. Record each joint with the specified and measured weld size and the surface defects seen. The form flags undersize welds, counts joints by result and by defect type (cracks, undercut, porosity, lack of fusion and others) and shows a note before anything is accepted. Try the form below, see every question or open a completed example.

Ready to use from the form library, and every question is yours to edit. Try it for a small trial fee, cancel any time.

Try it on your phone

Try it on this phone

Fill in the welding inspection on your phone now

See how the welding inspection looks on your phone

Scan the code with your phone camera. It opens the real form, no sign-up needed.

Open the live example and fill it in, just as your team would on site. No sign-up needed.

See it on this phone

Every question is editable. Add this form to your account, then change the wording, add or remove questions and options, and make it fit your own jobs.

Or start your trial with this form ready →

One email, and we won't add you to a mailing list.

How are welds assessed?

TWI describes visual inspection against relevant codes, standards and project requirements. Record the applicable procedure, acceptance criteria and actual observations; additional testing depends on the specified inspection scope.

Last updated . Facts checked by the SiteSurvey team on 20 October 2026 against TWI visual inspection of welds and BCSA guidance on steelwork quality and specification.

Built for visual weld inspection

Record each joint with the specified and measured weld size and the surface defects seen. The form flags undersize welds, counts joints by result and by defect type, and shows a note before anything with a crack, a repair or a review is accepted.

Joint J-04: specified weld size 8 mm, smallest measured 7 mm, result Undersize by 1 mm, with Undercut ticked under surface defects

Weld size against the drawing

Enter the specified size from the drawing or WPS and the smallest gauge reading. The form shows an undersize weld and by how much.

How calculated fields work →
Joints with each defect type: cracks 0, undercut 1, porosity 1, lack of fusion 0, overlap, spatter or uneven profile 1

Defects by type

Tick the defects seen on each joint and the form counts joints with cracks, undercut, porosity, lack of fusion and others. A crack brings up a red note; repairs bring up an amber one.

How calculated fields work →

Walk Cam along the weld

Walk Cam records the weld with a guided point for each check and turns what you say into text.

A completed welding inspection

A fictional mezzanine frame: four joints, J-04 undersize at 7 mm against 8 mm with undercut, J-09 with surface porosity, both sent for repair and reinspection, and two joints accepted visually.

A fillet weld gauge resting against a fillet weld where an end plate meets a beam web
J-01 · 8 mm leg on the gauge
A fillet weld on an end plate with undercut at the toe
J-04 · undercut and 7 mm leg · repaired

Try the welding inspection form live

Answer a few questions and watch it adapt. Your answers are not saved, and any photos you add are deleted within the hour.

Live form: Welding InspectionOpen full screen ↗
Fill it in right here

This is the real form as your team would use it: questions appear as you answer, scores work themselves out and you can add photos and signatures. No sign-up needed. Or open a completed example to see every answer, photo and score filled in.

Want to see one filled in? See a completed welding inspection report (PDF), made by SiteSurvey from a fictional site visit.

Walk Cam route · four guided clips

Record the welding inspection on video

Show the component, the joint and the full bead before filming a local surface detail. Keep every observation attached to a weld identifier and review stage.

Record the component and weld identifier, work stage, drawing or procedure reference, and the person responsible for formal inspection. Film the accessible weld surface in adequate light, from whole joint to detail, without disturbing the component.

See the footage in a report

A fictional six-page example with the four points, twelve stills from the clips, observations, follow-up actions and the limits of a visual record.

View the visual evidence (PDF) ↗ · Download the full sample report

Visual evidence page from the visual weld surface inspection sample report, with footage stills and observations

Phone footage records visible surfaces only. It cannot measure the weld, reveal internal flaws or establish acceptance. A competent inspector must apply the specified procedure and criteria. Example footage was generated in Google Flow and the observations are scripted; no real site is shown. Walk Cam works inside any form in the app. How Walk Cam works · All visual inspections

Fill it in on a phone or tablet

Your team completes the welding inspection on site in the SiteSurvey app on iPhone, iPad and Android phones and tablets. The project name and address fill in for them, it works without signal, and it syncs when the device is back online with photos kept against the question they answer.

Customers and subcontractors do not need the app: send them a link and they can fill it in from any browser.

The Welding Inspection form in the SiteSurvey app on a tablet
The Welding Inspection form in the SiteSurvey app on a phone

Every question in the welding inspection template

A welding inspection record with joint identification, procedure and welder references, preparation checks, visual findings, NDT links and repair history. 5 sections and 58 questions. Follow-up questions and guidance appear only when an answer calls for them, so the person on site never sees the ones that do not apply.

Make it your own: every question is editable

This is a starting point, not a fixed form. Once it is in your SiteSurvey account you can reword any question, add or remove questions, sections and answer options, and add your own logo, so it fits the way your team works and the jobs you do.

Details you only enter once

Add this form to a project in SiteSurvey and it fills in what the project already knows, so nobody on site retypes it and every form on the job uses the same names. Anything filled in can still be changed.

  • Project: the project name
  • Client or organisation: the project's customer
  • Site or premises address: the site address, from the space or the project

Record details and scope

  • ProjectShort answer

    Filled in from the project in SiteSurvey.

    Fills in from the project name
  • Client or organisationShort answer
    Fills in from the project's customer
  • Site or premises addressShort answer
    Fills in from the site address, from the space or the project
  • Record date*Date
  • Person completing the record*Short answer
  • CheckFor competent welding inspection. This is not a welder qualification, approved welding procedure, NDT report or automatic acceptance of a welded joint.
  • CheckVisual testing of fusion welds follows BS EN ISO 17637, and the acceptance levels for imperfections in steel welds come from BS EN ISO 5817 (quality levels B, C and D, set by the design or execution standard). Welders are qualified to BS EN ISO 9606-1 and welding procedures to BS EN ISO 15614-1 (or another route allowed by the specification). For structural steelwork, BS EN 1090-2 sets the execution class, the inspection extent and the quality level. Record the procedure, the welder, the acceptance level used and what was actually seen; further testing depends on the specification.

Job and procedure

  • Job, assembly and drawing revision*Short answer
  • Welding procedure specification and revision*Short answer
  • Welder ID and qualification referenceShort answer
  • Inspector and competence reference*Short answer
  • Inspection plan and acceptance standard with edition*Short answer

    Identify the acceptance criteria and document revision before recording a result. Avoid substituting a general visual opinion for the specified assessment.

Joint inspection

  • Weld joint
    Repeat for each weld joint. Each one asks:
    • Joint or weld ID*Short answer
    • Material and consumable traceability referencesShort answer
    • Preparation, fit-up and pre-weld checksNotes
    • In-process observations and specified parameter evidenceNotes
    • Post-weld visual findings and dimensions*Notes
    • Specified weld size (mm)Number

      Leg length or throat, as given on the drawing or WPS.

    • Smallest measured weld size (mm)Number

      By weld gauge, on the same basis as the specified size.

    • Measured against specified sizeWorked out by the form
      Shown only when the answers above make it relevant
    • Undersize by (mm)Worked out by the form
      Shown only when the answers above make it relevant
    • Surface defects seenTick all that apply
      • Crack
      • Undercut
      • Porosity
      • Lack of fusion
      • Overlap
      • Spatter
      • Uneven profile
      • None seen
    • Result*Choose one
      • Meets recorded visual criteria
      • Repair or review required
      • Not fully inspected
    • Separate NDT method and report referenceShort answer
    • Supporting photosPhotos
    • d_crackWorked out by the form
    • d_undercutWorked out by the form
    • d_porosityWorked out by the form
    • d_lofWorked out by the form
    • d_otherWorked out by the form
    • d_underWorked out by the form
    • is_meetsWorked out by the form
    • is_repairWorked out by the form
    • is_partialWorked out by the form
  • Joints inspectedWorked out by the form
  • Meet the visual criteriaWorked out by the form
  • Repair or reviewWorked out by the form
  • Not fully inspectedWorked out by the form
  • Undersize weldsWorked out by the form
  • GuidanceJoints with each defect type
  • CracksWorked out by the form
  • UndercutWorked out by the form
  • PorosityWorked out by the form
  • Lack of fusionWorked out by the form
  • Overlap, spatter or uneven profileWorked out by the form
  • WarningA crack is recorded. Do not accept the joint or load the assembly: refer it to the responsible engineer for a repair instruction and any NDT.
    Shown only when the answers above make it relevant
  • CheckJoints need repair or review. Do not accept them until the repair is reinspected and any NDT is reported.
    Shown only when the answers above make it relevant
  • Walk Cam: visual weld surface inspectionWalk Cam video with voice-to-text

    Optional. Film the four guided points on the SiteSurvey app; each clip keeps its spoken note.

Repair and closure

  • Approved repair instruction and affected weld IDsNotes
  • Reinspection and NDT report referencesNotes
  • Authorised acceptance reference and limitationsShort answer

Actions and review

  • Are further actions required?Choose one
    • Yes
    • No
  • Further action
    Repeat for each further action. Each one asks:
    Shown when “Are further actions required?” is “Yes”
    • Action and evidence reference*Notes
    • PriorityChoose one
      • Urgent
      • High
      • Medium
      • Low
    • Person responsibleShort answer
    • Target dateDate
    • Action statusChoose one
      • Open
      • In progress
      • Completed
    • Completion evidence*Notes
      Shown when “Action status” is “Completed”
  • Outstanding limitations and information to pass onNotes
  • Record status*Choose one
    • Ready for review
    • Further work needed
    • Work or use stopped
  • Reviewed byShort answer
  • Review dateDate
  • Author signature*Signature
  • CheckSigning records the information entered. It does not itself certify legal compliance, remove a limitation or authorise unsafe work.

Scope and responsibility

For competent welding inspection. This is not a welder qualification, approved welding procedure, NDT report or automatic acceptance of a welded joint.

What a useful entry looks like

Inspection plan and acceptance standard with edition

Identify the acceptance criteria and document revision before recording a result. Avoid substituting a general visual opinion for the specified assessment.

Joint J-18 assessed against the acceptance criteria referenced in inspection plan WI-03 revision B. Additional testing is recorded by report reference.

Fictional example of record wording. Use the actual evidence and approved arrangements for your job; this is not a completed report or an instruction to carry out the work.

See it filled in

A completed welding inspection report, made by SiteSurvey from a fictional site visit: every answer, the photos, the guidance that applied and the sign-off, ready to send as a PDF.

See completed form (PDF) ↗

Welding Inspection FAQs

How does the form count weld defects?

Tick the surface defects seen on each joint. The review shows how many joints have cracks, undercut, porosity, lack of fusion, or overlap, spatter or an uneven profile, and how many welds are smaller than specified from your gauge readings. Acceptance stays with the criteria in your specification and any NDT.

Can visual inspection prove every weld is sound?

No. Record the limitations and link any additional testing required by the project.

Does the form qualify a welder?

No. It records a qualification reference without issuing or renewing it.

How are repaired welds tracked?

Keep the original joint ID and finding, then link the approved repair instruction and reinspection evidence.

What are the limits of this template?

For competent welding inspection. This is not a welder qualification, approved welding procedure, NDT report or automatic acceptance of a welded joint.

Can I complete this form on site and share the record?

In the SiteSurvey app the form works offline, with photos and signatures recorded against the questions. Share the completed record as a PDF or a link. Dates and action owners are recorded fields; this form does not send reminders or update other systems.

Related

Hazards this form covers

Who each hazard harms, what the law expects and the control measures to look for, in our hazard library.

Use this welding inspection form with your team

Add it from the form library in one click, change any question, and every completed form becomes a branded PDF report.

Start your trial →