Skip to main content

Form library · Housing and property

Loft insulation survey

A survey before loft insulation is installed or topped up. Record the access, the loft's length and width, the existing insulation depth, which you can measure from a photo with a rule or an A4 sheet standing in the insulation, and the target depth for the job. The form works out the top-up, the area to insulate, the volume and the rolls needed, counts the things to deal with (ventilation, damp, downlights, the tank, asbestos) and holds the job if suspect asbestos, damp or unsafe access is found. Record the insulation proposed and whether it is funded. Try the form below, see every question or open a completed example.

Ready to use from the form library, and every question is yours to edit. Try it for a small trial fee, cancel any time.

Try it on your phone

Try it on this phone

Fill in the loft insulation survey on your phone now

See how the loft insulation survey looks on your phone

Scan the code with your phone camera. It opens the real form, no sign-up needed.

Open the live example and fill it in, just as your team would on site. No sign-up needed.

See it on this phone

Every question is editable. Add this form to your account, then change the wording, add or remove questions and options, and make it fit your own jobs.

Or start your trial with this form ready →

One email, and we won't add you to a mailing list.

What should be checked before insulating a loft?

Before insulating a loft, check safe access, the existing insulation depth and joist depth, that the eaves and ventilation will stay clear to avoid condensation, any damp or leaks, recessed downlights and cables that must not be covered, the cold water tank and pipes, any boarding or storage, and suspect asbestos. Record the loft area and the insulation proposed.

Last updated . Facts checked by the SiteSurvey team on 17 October 2026 against Haringey Council: loft insulation, Electrical Safety First: downlights, Ofgem: ECO4 supply chain requirements and HSE: where asbestos is found.

Built for surveying a loft before insulating

Check the loft with the form on a phone. Measure the existing depth from a photo, set the target depth, and the form works out the top-up, the area to insulate, the volume and the rolls needed, counts the things to deal with and holds the job if suspect asbestos, damp or unsafe access is found.

Existing insulation depth filled in as 90 mm with the marked-up measuring photo as a thumbnail

Existing depth from a photo

Stand an A4 sheet upright beside the insulation, photograph it from the side, tap both ends of the sheet and then the top and bottom of the insulation. Depth varies across a loft, so note any thin areas too. It works on web forms in any phone browser today, and the app version is on its way.

How measuring from a photo works →
Target total depth 270 mm, top-up needed 180 mm and the depth check Below the target: top up

Top-up and quantities

Against the target depth from the specification or the scheme, the form works out the top-up, the area to insulate after the tank and hatch areas, the volume to add and the rolls or packs needed.

How calculated fields work →
2 things to deal with before or during the install

Things to deal with, counted

Blocked ventilation, damp, downlights, the cold water tank, suspect asbestos and unsafe access are counted, and a red note stops the job if asbestos, damp or unsafe access is recorded.

How calculated fields work →

A completed loft insulation survey

A fictional semi with about 90 mm of old mineral wool, measured from a photo against an A4 sheet, topped up to 270 mm over 48.5 m², with downlights to cover and a cold water tank to insulate. Open it as a filled-in form, or switch to a blank copy and try it yourself.

Old yellow mineral wool between joists in a loft with an A4 sheet standing beside its cut edge, marked up to give a depth of about 90 mm
Existing depth about 90 mm · target 270 mm
Mineral wool insulation laid between the joists and up the roof slope in a loft
Across the loft before the top-up
Across a loft with old insulation and the cold water tank

Try the loft insulation survey form live

Answer a few questions and watch it adapt. Your answers are not saved, and any photos you add are deleted within the hour.

Live form: Loft Insulation Pre-install SurveyOpen full screen ↗
Fill it in right here

This is the real form as your team would use it: questions appear as you answer, scores work themselves out and you can add photos and signatures. No sign-up needed. Or open a completed example to see every answer, photo and score filled in.

Want to see one filled in? See a completed loft insulation survey report (PDF), made by SiteSurvey from a fictional site visit.

Every question in the loft insulation survey template

A loft insulation pre-install survey: access, existing insulation depth, joists, ventilation and condensation, cables and downlights, tanks and pipes, boarding and storage, area and the work proposed. 3 sections and 43 questions. Follow-up questions and guidance appear only when an answer calls for them, so the person on site never sees the ones that do not apply.

Make it your own: every question is editable

This is a starting point, not a fixed form. Once it is in your SiteSurvey account you can reword any question, add or remove questions, sections and answer options, and add your own logo, so it fits the way your team works and the jobs you do.

Details you only enter once

Add this form to a project in SiteSurvey and it fills in what the project already knows, so nobody on site retypes it and every form on the job uses the same names. Anything filled in can still be changed.

  • Project: the project name
  • Client: the project's customer
  • Site: the site, when the form is opened for a space or a product
  • Site address: the site address, from the space or the project

Loft

  • ProjectShort answer
    Fills in from the project name
  • ClientShort answer
    Fills in from the project's customer
  • Site*Short answer
    Fills in from the site, when the form is opened for a space or a product
  • Site addressShort answer
    Fills in from the site address, from the space or the project
  • Survey date*Date
  • Surveyor*Short answer
  • Safe access hatch and ladder?Yes or No
  • Loft length (m)Number

    Measuring from a photo gives an estimate. Use a tape or laser where the figure matters.

  • Loft width (m)Number

    Measuring from a photo gives an estimate. Use a tape or laser where the figure matters.

  • Loft area (m²)Worked out by the form
    Shown only when the answers above make it relevant
  • Existing insulation depth (mm)Number

    Stand a rule, or an A4 sheet on its long edge, upright in the insulation and photograph it from the side; use it as the reference. Depth varies across a loft, so record a typical reading and note thin areas.

  • Joist depth (mm)Number
  • Existing insulationChoose one
    • None
    • Mineral wool
    • Loose fill
    • Boards
    • Mixed
  • Target total depth for this job (mm)Number

    From the specification or the funding scheme.

  • Top-up needed (mm)Worked out by the form
    Shown only when the answers above make it relevant
  • Depth checkWorked out by the form
    Shown only when the answers above make it relevant
  • Area left uninsulated or not reached (m²)Number

    For example under the cold water tank, the hatch, or boarding that is staying down.

  • Area to insulate (m²)Worked out by the form
    Shown only when the answers above make it relevant
  • Insulation to add (m³)Worked out by the form
    Shown only when the answers above make it relevant
  • Coverage of one roll or pack at the top-up depth (m²)Number

    From the product label.

  • Rolls or packs needed (before waste, round up)Worked out by the form
    Shown only when the answers above make it relevant
  • Walk Cam: loft surveyWalk Cam video with voice-to-text

    Optional. Film a guided walk-through on the SiteSurvey app.

Checks

  • Ventilation at the eaves or ridgeChoose one
    • Clear
    • Blocked
    • None found
  • CheckKeep the eaves and ventilation paths clear when insulating, or the loft can suffer condensation.
    Shown only when the answers above make it relevant
  • GuidanceSources. Approved Document L (conservation of fuel and power) sets the insulation standard for roofs when they are renovated or a new loft is insulated. BS 5250:2021, Management of moisture in buildings, covers condensation risk and the ventilation of cold roof spaces. Follow the insulation maker's instructions and any funding scheme rules.
  • Any damp, condensation, mould or leaks?Yes or No
  • WarningFix damp and leaks before insulating.
    Shown when “Any damp, condensation, mould or leaks?” is Yes
  • Recessed downlights in the ceiling below?Yes or No
  • CheckDo not cover downlights unless they are rated for it; fit covers or keep insulation clear. Lift cables above the insulation where you can.
    Shown when “Recessed downlights in the ceiling below?” is Yes
  • Cold water tank or pipes in the loft?Yes or No
  • CheckLeave the ceiling under the cold water tank uninsulated, and insulate the tank and pipes, so they do not freeze.
    Shown when “Cold water tank or pipes in the loft?” is Yes
  • Is the loft boarded or used for storage?Yes or No
  • Any suspect asbestos (old loose fill, boards, flue pipes)?Yes or No
  • WarningHSE: loose-fill asbestos, a loose fluffy insulation that may be blue-grey or whitish, can be found in loft spaces, and only an HSE-licensed contractor may work on it. Do not disturb suspect material. Arrange an asbestos survey before any work.
    Shown when “Any suspect asbestos (old loose fill, boards, flue pipes)?” is Yes
  • Things to deal with before or during the installWorked out by the form
  • WarningDo not start yet. Suspect asbestos, damp or unsafe access was recorded. Resolve it, or arrange the survey or repair, before anyone works in the loft.
    Shown only when the answers above make it relevant
  • PhotosPhotos
  • Issues to resolve before installing
    Repeat for each action. Each one asks:
    • Action needed*Notes
    • PriorityChoose one
      • Urgent
      • High
      • Medium
      • Low
    • Who will do itShort answer
    • Due byDate
    • StatusChoose one
      • Open
      • In progress
      • Completed
    • PhotosPhotos

Proposal

  • Insulation proposed (material and depth)Short answer
  • Is it funded under a government scheme?Yes or No
  • CheckOfgem: installers on ECO4 must be TrustMark registered, and ECO4 measures follow the PAS 2035 retrofit process. Check the rules of the scheme funding this job.
    Shown when “Is it funded under a government scheme?” is Yes
  • Notes for the installerNotes
  • Customer nameShort answer
  • Customer signatureSignature
  • Completed byWorked out by the form
  • Surveyor signatureSignature

See it filled in

A completed loft insulation survey report, made by SiteSurvey from a fictional site visit: every answer, the photos, the guidance that applied and the sign-off, ready to send as a PDF.

See completed form (PDF) ↗

Loft insulation survey FAQs

Why keep the eaves clear?

Ventilation stops condensation forming in the loft, so the openings into the loft from the eaves must not be blocked when laying insulation.

What about downlights and cables?

Electrical Safety First says not to let downlights be covered by loft insulation unless they are designed and rated for it. Route cables above the insulation where you can, to reduce the risk of overheating.

Should the water tank be insulated?

Yes. Insulate the tank and pipes, and leave the ceiling under the tank uninsulated, to guard against freezing and burst pipes.

What if it is a funded scheme?

Ofgem says installers delivering ECO4 measures must be TrustMark registered, and ECO4 projects follow the PAS 2035 retrofit process. Check the rules of the scheme funding the job. The form flags this.

What about asbestos?

HSE says loose-fill asbestos, a loose fluffy insulation that may be blue-grey or whitish, can be found in loft spaces, and only an HSE-licensed contractor may work on it. Do not disturb suspect material, and arrange a survey before any work.

Who uses this?

Insulation installers, retrofit coordinators, energy assessors and housing providers.

Related

Use this loft insulation survey form with your team

Add it from the form library in one click, change any question, and every completed form becomes a branded PDF report.

Start your trial →