A service visit record for door entry and intercom systems. Record the system, scan the panel label and say whether it is a high-rise residential building; if it is, the form works out the days since the last recorded monthly check of the fire alarm door release. Mark each entrance's location, check the panel, camera, lock, closer, fire alarm release and exit button, and the form counts the defects at each entrance and across the site. Check the power supply and battery backup, sample handsets in flats, and the form works out the share of flats sampled and the defects found. Try the form below, see every question or open a completed example.
✎Every question is editable. Add this form to your account, then change the wording, add or remove questions and options, and make it fit your own jobs.
An intercom and door entry service checks each entrance panel's buttons, speaker, microphone, camera and lighting, that the lock releases and holds, the door closer and alignment, the exit button and emergency break glass, and that doors release when the fire alarm operates. It also tests the power supply and battery backup and samples handsets in flats for calls, video and door release.
Mark each entrance's panel, check it, and the form counts the defects at each entrance and across the site. In a high-rise residential building it shows the days since the last recorded monthly check of the fire alarm door release. Handsets sampled are counted against the flats.
Monthly check of the fire release
In a high-rise residential building, enter the date of the responsible person's last recorded monthly check. Over a month, the form notes that regulation 7 asks for monthly routine checks of door release mechanisms linked to the fire alarm.
Stand at each panel and tap Mark current location. On an estate with several blocks the next engineer can find every panel. Mark current location works on web forms in any phone browser today, and the app version is on its way.
Each entrance counts its own defects. The form adds them up and counts the fire alarm releases with a fault, which in a high-rise building must be reported if not fixed within 24 hours.
Add each handset you sample. The form works out the share of flats sampled and totals the defects at the entrances, power supply, battery and handsets.
A fictional high-rise block of 24 flats with three entrances: a slamming closer, a car park door maglock that did not release on the fire alarm signal, a battery that failed its load test and a faulty handset, with the last monthly check 39 days before. Open it as a filled-in form, or switch to a blank copy and try it yourself.
This is the real form as your team would use it: questions appear as you answer, scores work themselves out and you can add photos and signatures. No sign-up needed. Or open a completed example to see every answer, photo and score filled in.
An intercom and door entry service record: system, entrance panels, lock release, door closer, power and battery backup, fire alarm door release, handsets sampled, faults and sign-off. 3 sections and 47 questions. Follow-up questions and guidance appear only when an answer calls for them, so the person on site never sees the ones that do not apply.
✎
Make it your own: every question is editable
This is a starting point, not a fixed form. Once it is in your SiteSurvey account you can reword any question, add or remove questions, sections and answer options, and add your own logo, so it fits the way your team works and the jobs you do.
Details you only enter once
Add this form to a project in SiteSurvey and it fills in what the project already knows, so nobody on site retypes it and every form on the job uses the same names. Anything filled in can still be changed.
Project: the project name
Client: the project's customer
Site: the site, when the form is opened for a space or a product
Site address: the site address, from the space or the project
Manufacturer and model: the product's manufacturer
1
System
ProjectShort answer
Fills in from the project name
ClientShort answer
Fills in from the project's customer
Site*Short answer
Fills in from the site, when the form is opened for a space or a product
Site addressShort answer
Fills in from the site address, from the space or the project
Service date*Date
Engineer*Short answer
SystemChoose one
Audio
Video
Audio and video with fob access
IP or app based
Other
Manufacturer and modelShort answer
Fills in from the product's manufacturer
Scan the panel labelScan a label: serial number, model number
Optional. Scan the label or tag to capture its numbers.
Flats or units servedNumber
Is it a residential building with two or more flats, at least 18 m high or with at least 7 storeys?Yes or No
2
Entrances
Entrance doors
Repeat for each entry. Each one asks:
Entrance*Short answer
Entrance locationShort answer
Stand at the panel and tap Mark current location. On estates with several blocks it shows the next engineer where each panel is.
Panel, buttons, speaker and microphoneChoose one
OK
Defect
Camera and lightingChoose one
OK
Defect
Not fitted
Lock or maglock releases and holdsChoose one
OK
Defect
Door closer and alignmentChoose one
OK
Defect
Releases on fire alarm signalChoose one
OK
Defect
Not linked
Exit button and emergency break glassChoose one
OK
Defect
Checks with a defect at this entranceWorked out by the form
What is wrong at this entrance?Short answer
Shown only when the answers above make it relevant
WarningThe fire alarm release has a fault in a high-rise residential building. Tell the responsible person now: if it cannot be fixed within 24 hours they must report it to the fire and rescue service.
Shown when “Releases on fire alarm signal” is “Defect” and “Is it a residential building with two or more flats, at least 18 m high or with at least 7 storeys?” is Yes
PhotosPhotos
Entrances servicedWorked out by the form
Entrances with a defectWorked out by the form
Defects found at entrancesWorked out by the form
Fire alarm releases with a faultWorked out by the form
CheckIn high-rise residential buildings in England, automatic door release mechanisms linked to the fire alarm system in the common parts are essential fire-fighting equipment under regulation 7 of the Fire Safety (England) Regulations 2022. The responsible person must check them every month, record the checks and make the record available to residents, and report to the fire and rescue service by electronic means any fault not fixed within 24 hours.
Shown when “Is it a residential building with two or more flats, at least 18 m high or with at least 7 storeys?” is Yes
Date of the last recorded monthly check of the fire alarm door releaseDate
Before today. From the responsible person's record of monthly checks.
Shown when “Is it a residential building with two or more flats, at least 18 m high or with at least 7 storeys?” is Yes
Days since that checkWorked out by the form
Shown when “Is it a residential building with two or more flats, at least 18 m high or with at least 7 storeys?” is Yes and “Date of the last recorded monthly check of the fire alarm door release” is answered and “Service date” is answered
CheckMore than a month since the last recorded check. Regulation 7 of the Fire Safety (England) Regulations 2022 asks for monthly routine checks: tell the responsible person.
Shown only when the answers above make it relevant
3
Power and handsets
Power supplyChoose one
OK
Defect
Battery backup testedChoose one
OK
Defect
Not fitted
Photos of the power supply, battery and handsetsPhotos
Handsets sampled
Repeat for each flat. Each one asks:
Flat*Short answer
Call, speech and videoChoose one
OK
Defect
Door releaseChoose one
OK
Defect
Handsets sampledWorked out by the form
Handsets with a defectWorked out by the form
Flats sampled (%)Worked out by the form
Shown only when the answers above make it relevant
Defects found (entrances, power and handsets)Worked out by the form
Result*Choose one
Working
Working with faults to fix
Not working
Faults and parts neededNotes
Shown only when the answers above make it relevant
Who will fix the faults, and by whenShort answer
Shown only when the answers above make it relevant
Next service dueDate
Set by the maintenance contract and the maker's instructions.
Days to next dueWorked out by the form
Shown when “Service date” is answered and “Next service due” is answered
CheckThe next service due date is before the inspection date. Check the date.
Shown only when the answers above make it relevant
Site contact nameShort answer
Site contact signatureSignature
Completed by*Short answer
SignatureSignature
See it filled in
A completed intercom service report, made by SiteSurvey from a fictional site visit: every answer, the photos, the guidance that applied and the sign-off, ready to send as a PDF.
In high-rise residential buildings in England (two or more flats, at least 18 metres or 7 storeys), automatic door release mechanisms linked to the fire alarm system are essential fire-fighting equipment under regulation 7. The responsible person must check them every month, record the checks and make the record available to residents, and report to the fire and rescue service any fault not fixed within 24 hours.
How many handsets should be tested?
Agree a sample with the client, for example a few flats on each floor, plus any reported faults. The form records each one tested.
What about the battery backup?
The form records whether the backup battery was tested, or that none is fitted, and the faults box records any replacement needed, so the client can see what was found.
Can I scan the panel label?
Yes. Scan the panel label on the SiteSurvey app to capture its serial and model numbers.
Does the client sign?
Yes. The site contact signs and the record goes as a PDF or a link.
Who uses this?
Door entry and access control engineers, managing agents, housing associations and facilities teams.