Skip to main content

Form library · Retail and hospitality

Hot tub inspection checklist

A water test and condition check for hot tubs and spa pools used by a business, to HSE HSG282. Pin the hot tub's position on a park, record its setting and type, the check, when it was last drained and refilled and whether the normal operating plan is on site. Enter the target pH and disinfectant ranges from your plan, then each water test: the form checks each reading against your targets, shows the HSG282 action limits and counts tests outside them. Check the dosing system, the water line, skimmer, jets, grilles, filter, cover, steps, cabinet and rules sign; the form counts defects and warns if the tub is open with a defect or after a test at the close limits. Try the form below, see every question or open a completed example.

Ready to use from the form library, and every question is yours to edit. Try it for a small trial fee, cancel any time.

Try it on your phone

Try it on this phone

Fill in the hot tub inspection on your phone now

See how the hot tub inspection looks on your phone

Scan the code with your phone camera. It opens the real form, no sign-up needed.

Open the live example and fill it in, just as your team would on site. No sign-up needed.

See it on this phone

Every question is editable. Add this form to your account, then change the wording, add or remove questions and options, and make it fit your own jobs.

Or start your trial with this form ready →

One email, and we won't add you to a mailing list.

What water test levels does HSG282 give for a hot tub?

HSE's HSG282 Table 3 gives a typical pH range of 7.0 to 7.6 and a typical disinfectant range of 3 to 5 mg/l free chlorine or 4 to 6 mg/l bromine. Outside pH 7.0 to 7.6, or with chlorine below 1 or above 10 mg/l (bromine below 2 or above 12 mg/l), close the spa pool, correct the fault and retest. Between those limits, check the dosing units are working. Combined chlorine above 1 mg/l means reviewing the control measures.

Last updated . Facts checked by the SiteSurvey team on 17 October 2026 against HSE HSG282: the control of legionella and other infectious agents in spa-pool systems and HSE: legionella and spa-pool systems.

Built for hot tub checks on parks and in hotels

Enter the target ranges from your normal operating plan, then each water test. The form checks each reading against your targets, shows the HSG282 action limits, counts tests outside them, works out the days since the last drain and refill, counts condition defects and warns if the tub is open with a defect or after a test at the close limits.

Test 1: chlorine 2.5 mg/l and combined chlorine 0.4: pH outside target and disinfectant outside target, with the HSG282 note below

Tests against your targets

Each test shows whether the pH and disinfectant are within the targets from your plan. HSG282's close and check-the-dosing limits are shown as notes.

How calculated fields work →
2 tests recorded, 1 outside your target, 1 at the HSG282 close limits

Tests and defects counted

The form counts the tests, those outside your targets and those at the HSG282 close limits. If the tub is then recorded as open, an amber note asks for the correction and retest.

How calculated fields work →
Last drained, cleaned and refilled 6 October: 3 days since

Days since the last drain

HSG282 Table 1 says to drain, clean and refill a domestic-type hot tub between each group of users or at least weekly. The form shows the days since and warns after 7.

How calculated fields work →
Hot tub position (GPS) recorded on the Lodge 7 deck

Each hot tub pinned

On a park with many lodges, pin the tub so the record and any contractor find the right one. It works on web forms in any phone browser today, and the app version is on its way.

How GPS location works →

Film the jets and grilles

Add photos of any defect, or film the check with Walk Cam on the SiteSurvey app.

A completed hot tub check

A fictional holiday lodge hot tub: the 09:15 test at pH 7.8 and 2.5 mg/l chlorine, outside the plan's targets and the HSG282 pH limit, so closed, the feeder refilled and retested in range at 10:05. Drained 3 days earlier. A worn top step recorded with a repair booked.

A grey plastic hot tub step with a worn smooth top tread on a lodge deck
Steps · top tread worn · new tread booked
A handheld water tester and sample tube on the edge of an open hot tub
Water tests · 09:15 and 10:05

Try the hot tub inspection form live

Answer a few questions and watch it adapt. Your answers are not saved, and any photos you add are deleted within the hour.

Live form: Hot Tub and Spa Pool CheckOpen full screen ↗
Fill it in right here

This is the real form as your team would use it: questions appear as you answer, scores work themselves out and you can add photos and signatures. No sign-up needed. Or open a completed example to see every answer, photo and score filled in.

Want to see one filled in? See a completed hot tub inspection report (PDF), made by SiteSurvey from a fictional site visit.

Walk Cam route · four guided clips

Record the hot tub inspection on video

Film the tub and surround, the cover and steps, the water, jets and grilles, and the closed equipment cabinet.

Record the site, unit, date and who checked. Keep guests out of shot. The four AI-generated clips illustrate one route, not a real hot tub.

See the footage in a report

A fictional six-page example with the four points, twelve stills from the clips, observations, follow-up actions and the limits of a visual record.

View the visual evidence (PDF) ↗ · Download the full sample report

Visual evidence page from the hot tub and spa pool check visual route sample report, with footage stills and observations

Video records visible condition. Water quality, disinfectant levels and microbiological testing are recorded separately under the site's written scheme. Example footage was generated in Google Flow and the observations are scripted; no real site is shown. Walk Cam works inside any form in the app. How Walk Cam works · All visual inspections

Every question in the hot tub inspection template

A hot tub and spa pool check to HSE HSG282: water clarity, pH and disinfectant tests with HSG282 action limits, jets, overflows, grilles and filter, cover, steps and cabinet, cleaning done, open or closed, and sign-off. 4 sections and 73 questions. Follow-up questions and guidance appear only when an answer calls for them, so the person on site never sees the ones that do not apply.

Make it your own: every question is editable

This is a starting point, not a fixed form. Once it is in your SiteSurvey account you can reword any question, add or remove questions, sections and answer options, and add your own logo, so it fits the way your team works and the jobs you do.

Details you only enter once

Add this form to a project in SiteSurvey and it fills in what the project already knows, so nobody on site retypes it and every form on the job uses the same names. Anything filled in can still be changed.

  • Project: the project name
  • Client: the project's customer
  • Site: the site, when the form is opened for a space or a product
  • Site address: the site address, from the space or the project

Hot tub

  • ProjectShort answer
    Fills in from the project name
  • ClientShort answer
    Fills in from the project's customer
  • Site*Short answer
    Fills in from the site, when the form is opened for a space or a product
  • Site addressShort answer
    Fills in from the site address, from the space or the project
  • Check date*Date
  • Checked by*Short answer
  • Hot tub or spa pool (unit or location)*Short answer
  • Hot tub position (GPS)Short answer

    On a park with many lodges, stand by the tub and tap Mark current location, so the record and any contractor find the right one. Mark current location works on web forms today; the app version is on its way.

  • SettingChoose one
    • Holiday park or lodge
    • Hotel room
    • Hotel or leisure spa
    • Gym or club
    • Showroom or display
    • Other
  • TypeChoose one
    • Domestic-type hot tub
    • Commercial-type spa pool
  • CheckChoose one
    • Routine water test
    • Between lettings (drain, clean and refill)
    • Weekly check
    • Monthly check
  • Last drained, cleaned and refilledDate
  • Days since it was drained and refilledWorked out by the form
    Shown when “Last drained, cleaned and refilled” is answered and “Check date” is answered
  • Next drain, clean and refill dueDate

    HSG282 Table 1, domestic-type hot tubs: between each group of users or at least weekly, whichever is shorter. Commercial spa pools: as your written scheme sets.

  • CheckMore than 7 days since this domestic-type hot tub was drained, cleaned and refilled. HSG282 Table 1 says to do it between each group of users or at least weekly, whichever is shorter.
    Shown only when the answers above make it relevant
  • StateChoose one
    • In use
    • Not in use
  • Is the written control scheme (normal operating plan) on site?Yes or No
  • GuidanceHSE HSG282 covers the control of legionella and other infectious agents in spa pools. Domestic-type hot tubs used as part of a business, for example in a holiday park rental unit or a hotel bedroom, are subject to the general duties of the Health and Safety at Work etc. Act 1974. HSG282 says records of monitoring, inspections, tests and checks should be kept for at least five years, and should show who did the work and when.

Water tests

  • GuidanceHSG282 Table 1, domestic-type hot tubs: check water clarity, pH and disinfectant at least twice a day depending on the risk assessment and use; drain, clean the whole system and refill between each group of users or at least weekly, whichever is shorter. For commercial-type spa pools, test at opening and every two hours. Follow your own risk assessment.
  • GuidanceYour target ranges. Enter the ranges from your normal operating plan. HSG282 Table 3 gives typical ranges of pH 7.0 to 7.6, and 3 to 5 mg/l free chlorine or 4 to 6 mg/l total active bromine; your plan may set its own.
  • Target pH, lowestNumber
  • Target pH, highestNumber
  • Target disinfectant, lowest (mg/l)Number
  • Target disinfectant, highest (mg/l)Number
  • Water tests
    Repeat for each test. Each one asks:
    • Time*Time
    • Water clarityChoose one
      • Clear
      • Cloudy
    • pHNumber
    • DisinfectantChoose one
      • Chlorine
      • Bromine
    • Free chlorine or total active bromine (mg/l)Number
    • Combined chlorine (mg/l)Number
      Shown when “Disinfectant” is “Chlorine”
    • pH against your targetWorked out by the form
      Shown only when the answers above make it relevant
    • Disinfectant against your targetWorked out by the form
      Shown only when the answers above make it relevant
    • f_offWorked out by the form
    • f_closeWorked out by the form
    • f_rowWorked out by the form
    • WarningpH outside 7.0 to 7.6. HSG282 Table 3: close the spa pool and check the operation and calibration of the dosing units, then recheck.
      Shown only when the answers above make it relevant
    • WarningDisinfectant outside the HSG282 Table 3 limits (chlorine below 1 or above 10 mg/l, bromine below 2 or above 12 mg/l): close the spa pool, apply corrective actions and retest.
      Shown only when the answers above make it relevant
    • CheckDisinfectant outside the typical range (chlorine 3 to 5 mg/l, bromine 4 to 6 mg/l). HSG282 Table 3: check the dosing units are operating correctly.
      Shown only when the answers above make it relevant
    • CheckCombined chlorine above 1 mg/l. HSG282 Table 3: review the control measures.
      Shown only when the answers above make it relevant
    • Action takenChoose one
      • Closed until corrected
      • Corrected and retested
      Shown when “Water clarity” is “Cloudy”
  • Tests recordedWorked out by the form
  • Tests outside your targetWorked out by the form
  • Tests at the HSG282 close limitsWorked out by the form
  • Dosing system workingChoose one
    • OK
    • Defect
    • Not fitted
  • Microbiological sample taken today?Yes or No
  • Sample reference and laboratoryShort answer
    Shown when “Microbiological sample taken today?” is Yes
  • GuidanceHSG282 Table 1 typical frequency: microbiological testing monthly (aerobic colony count, coliforms, E. coli, P. aeruginosa) and quarterly for legionella.
    Shown when “Microbiological sample taken today?” is Yes
  • Next microbiological sample dueDate

    HSG282 Table 1 typical frequency: monthly microbiological testing and quarterly legionella testing, or as your written scheme sets.

Condition

  • GuidanceHSG282 says the review of a spa pool should include inspecting the accessible parts for damage and signs of contamination, such as biofilms, and the condition of the jets, overflows and grilles.
  • Water line cleanChoose one
    • OK
    • Defect
    • Not applicable
  • What is wrong?Short answer
    Shown when “Water line clean” is “Defect”
  • Overflow channels and skimmer cleanChoose one
    • OK
    • Defect
    • Not applicable
  • What is wrong?Short answer
    Shown when “Overflow channels and skimmer clean” is “Defect”
  • Jets: no damage, blockage or biofilmChoose one
    • OK
    • Defect
    • Not applicable
  • What is wrong?Short answer
    Shown when “Jets: no damage, blockage or biofilm” is “Defect”
  • Suction grilles and strainers in place and undamagedChoose one
    • OK
    • Defect
    • Not applicable
  • What is wrong?Short answer
    Shown when “Suction grilles and strainers in place and undamaged” is “Defect”
  • Filter cartridge cleanChoose one
    • OK
    • Defect
    • Not applicable
  • What is wrong?Short answer
    Shown when “Filter cartridge clean” is “Defect”
  • Cover, straps and locks secureChoose one
    • OK
    • Defect
    • Not applicable
  • What is wrong?Short answer
    Shown when “Cover, straps and locks secure” is “Defect”
  • Steps and surround: no damage or slip hazardChoose one
    • OK
    • Defect
    • Not applicable
  • What is wrong?Short answer
    Shown when “Steps and surround: no damage or slip hazard” is “Defect”
  • Equipment cabinet closed and secureChoose one
    • OK
    • Defect
    • Not applicable
  • What is wrong?Short answer
    Shown when “Equipment cabinet closed and secure” is “Defect”
  • User rules sign displayedChoose one
    • OK
    • Defect
    • Not applicable
  • What is wrong?Short answer
    Shown when “User rules sign displayed” is “Defect”
  • Condition checks with a defectWorked out by the form
  • Condition checks OKWorked out by the form
  • Done at this visitTick all that apply
    • Water line cleaned
    • Drained, cleaned and refilled
    • Filter cartridge cleaned or replaced
    • Pipework and jets inspected
    • Flexible hoses disinfected
    • Input air filter cleaned
  • Photos of defectsPhotos
  • Walk Cam: hot tub and spa pool checkWalk Cam video with voice-to-text

    Optional. Film the four guided points on the SiteSurvey app; each clip keeps its spoken note.

Actions and sign-off

  • Result*Choose one
    • Open for use
    • Closed until corrected
  • Why closedShort answer
    Shown when “Result” is “Closed until corrected”
  • CheckA test reached the HSG282 close limits and the hot tub is recorded as open. Record in the actions what was corrected and the retest that allowed it to reopen.
    Shown only when the answers above make it relevant
  • CheckA condition check has a defect and the hot tub is recorded as open. Record why it is safe to use, or the action and its date.
    Shown only when the answers above make it relevant
  • Are further actions needed?Yes or No
  • Further actions
    Repeat for each action. Each one asks:
    Shown when “Are further actions needed?” is Yes
    • What needs doing?*Notes
    • PriorityChoose one
      • Urgent
      • High
      • Medium
      • Low
    • Who will do it?Short answer
    • Due dateDate
    • StatusChoose one
      • Open
      • In progress
      • Completed
  • Inspector nameWorked out by the form
  • Position or companyShort answer
  • Inspector signatureSignature
  • CheckSigning records what was found on the day. It is not a guarantee of condition and does not replace any examination, test, design check or repair needed from a competent person.

Scope and responsibility

This is a routine check record, not a legionella risk assessment, a laboratory result or the site's written control scheme.

What a useful entry looks like

Test results, action taken and open or closed

Record each test with its time and the action taken when a result is outside the HSG282 range. Say whether the hot tub was closed, what was corrected and the retest.

09:15 pH 7.8, chlorine 2.5 mg/l: closed, feeder refilled and pH adjusted. 10:05 retest pH 7.4, chlorine 3.5 mg/l: reopened.

Fictional example of record wording. Use the actual evidence and approved arrangements for your job; this is not a completed report or an instruction to carry out the work.

See it filled in

A completed hot tub inspection report, made by SiteSurvey from a fictional site visit: every answer, the photos, the guidance that applied and the sign-off, ready to send as a PDF.

See completed form (PDF) ↗

Hot tub inspection FAQs

Does HSG282 apply to holiday lodge hot tubs?

Yes. HSG282 says domestic-type spa pools or hot tubs used as part of a business, for example in a holiday park rental unit or a hotel bedroom with its own spa, are subject to the general duties of the Health and Safety at Work etc. Act 1974 and must be managed and controlled in proportion to the risk.

How often should a hot tub be tested?

HSG282 Table 1 gives typical frequencies for domestic-type hot tubs: check water clarity, pH and disinfectant at least twice a day depending on the risk assessment and use, drain, clean and refill between each group of users or at least weekly, whichever is shorter, inspect pipework and jets weekly, and test microbiologically monthly and for legionella quarterly. The form shows the days since the last drain and refill, and warns after 7 days for a domestic-type hot tub.

What should the inspection look at?

HSG282 says the review should include inspecting the accessible parts for damage and signs of contamination, such as biofilms, and the condition of the jets, overflows and grilles. The form also checks the filter, cover and straps, steps, cabinet and rules sign.

How long should hot tub records be kept?

HSG282 says records of monitoring, inspections, tests and checks should be kept for at least five years, and the risk assessment record for as long as it is current and at least two years after. Records should show who did the work and when, and be signed.

Why does legionella matter in hot tubs?

HSE says spa-pool systems, including hot tubs, are a recognised source of diseases caused by infectious agents, including the organism that causes Legionnaires' disease, with outbreaks linked to leisure centres, hotels and holiday homes.

Can I film the check?

Yes. Add the optional Walk Cam route on the SiteSurvey app: the hot tub and surroundings, cover, straps and steps, water, jets and grilles, and the equipment cabinet and signs. Water tests are recorded in the form.

Related

Use this hot tub inspection form with your team

Add it from the form library in one click, change any question, and every completed form becomes a branded PDF report.

Start your trial →