A site survey for air source and ground source heat pumps. Record the property, current heating fuel and insulation, then measure every heated room with its design temperature, external walls, glazing and radiator, ready for the room-by-room heat loss calculation; ceiling heights can be measured from a photo with a door as the reference. The form works out each room's area and volume and totals the floor area, volume and glazing. Once your calculation is done, enter each room's heat loss and the form adds them up; it does not calculate heat loss. Pin the outdoor unit position with GPS, check the clearances against the manufacturer's minimums and record the distance to the nearest neighbouring window for the noise check, plus cylinder space and electrics. Try the form below, see every question or open a completed example.

Ready to use from the form library, and every question is yours to edit. Try it for a small trial fee, cancel any time.

Try it on your phone

Try it on this phone

Fill in the heat pump survey on your phone now

See how the heat pump survey looks on your phone

Scan the code with your phone camera. It opens the real form, no sign-up needed.

Open the live example and fill it in, just as your team would on site. No sign-up needed.

See it on this phone

Every question is editable. Add this form to your account, then change the wording, add or remove questions and options, and make it fit your own jobs.

Or start your trial with this form ready →

One email, and we won't add you to a mailing list.

What does a heat pump survey involve?

A heat pump survey records the property and its current heating, the insulation and fabric, and every heated room's dimensions, design temperature, external walls, glazing area and heat emitters, which are the inputs to a room-by-room heat loss calculation. It also checks where the outdoor unit can go, the pipe route and condensate drainage, space for a hot water cylinder and the electrical supply.

Last updated . Facts checked by the SiteSurvey team on 17 October 2026 against GOV.UK: Boiler Upgrade Scheme, what you can get, GOV.UK: Boiler Upgrade Scheme, check if you're eligible and MCS standards library: MIS 3005-D, the heat pump design standard.

Built for surveying a home for a heat pump

Measure every heated room on a phone, pin the outdoor unit position and check its clearances, and the form totals the floor area, volume and glazing. Once your heat loss calculation is done, enter each room's figure and the form adds them up; it does not calculate heat loss.

Outdoor unit position filled in as Side of the house by the oil tank with GPS coordinates, a grid reference and a View on map link

Pin the outdoor unit position

Stand where the unit would go and tap Mark current location, so the installer, the base and the noise check all use the same spot. Mark current location works on web forms in any phone browser today, and the app version is on its way.

How GPS location works →
Manufacturer's minimums of 1 m in front and 0.3 m to the side, and the clearance check Meets the clearances in the manual

Clearances against the manual

Enter the clear space in front of and beside the position, and the minimums from the manual of the unit you plan to fit. The form says whether the position meets them, before anyone pours a slab.

How calculated fields work →
Totals: 51.5 m² heated floor area, 4 heated rooms, 126.1 m³ volume, 7.6 m² glazing, glazing 15% of the floor area and 3,470 W of room heat losses entered

Room totals for the design

Each room's area and volume add up to the heated floor area and volume, with the glazing area and its share of the floor. Room heat losses from your calculation are added up too.

How calculated fields work →
Ceiling height (m) filled in as 2.61 with the marked-up measuring photo as a thumbnail

Ceiling height from a photo

Photograph a wall square on with a door in it, tap the top and bottom of the door, then the floor and the ceiling. It works on web forms in any phone browser today, and the app version is on its way.

How measuring from a photo works →

A completed heat pump site survey

A fictional 1930s oil-heated cottage: four rooms with 3,470 W of room heat losses from the design, a living room ceiling of about 2.61 m measured from a photo, and the outdoor unit pinned by the oil tank with room to spare against the manual. Open it as a filled-in form, or switch to a blank copy and try it yourself.

The side of a rendered cottage with a green plastic oil tank on a slab, a gravel path and a timber fence
Outdoor unit position by the oil tank
A living room wall with a panelled door and a radiator, marked up to give the ceiling height as about 2.61 m against the door
Living room · ceiling about 2.61 m
Along the side of the cottage to the unit position

Try the heat pump survey form live

Answer a few questions and watch it adapt. Your answers are not saved, and any photos you add are deleted within the hour.

Live form: Heat Pump Site SurveyOpen full screen ↗
Fill it in right here

This is the real form as your team would use it: questions appear as you answer, scores work themselves out and you can add photos and signatures. No sign-up needed. Or open a completed example to see every answer, photo and score filled in.

Want to see one filled in? See a completed heat pump survey report (PDF), made by SiteSurvey from a fictional site visit.

Every question in the heat pump survey template

A heat pump site survey: property, current heating and insulation, room-by-room measurements and emitters for the heat loss calculation, outdoor unit position, hot water cylinder space and electrics. 6 sections and 69 questions. Follow-up questions and guidance appear only when an answer calls for them, so the person on site never sees the ones that do not apply.

Make it your own: every question is editable

This is a starting point, not a fixed form. Once it is in your SiteSurvey account you can reword any question, add or remove questions, sections and answer options, and add your own logo, so it fits the way your team works and the jobs you do.

Details you only enter once

Add this form to a project in SiteSurvey and it fills in what the project already knows, so nobody on site retypes it and every form on the job uses the same names. Anything filled in can still be changed.

  • Project: the project name
  • Client: the project's customer
  • Site: the site, when the form is opened for a space or a product
  • Site address: the site address, from the space or the project

Property

  • ProjectShort answer
    Fills in from the project name
  • ClientShort answer
    Fills in from the project's customer
  • Site*Short answer
    Fills in from the site, when the form is opened for a space or a product
  • Site addressShort answer
    Fills in from the site address, from the space or the project
  • Survey date*Date
  • Surveyor*Short answer
  • Property typeChoose one
    • Detached house
    • Semi-detached house
    • Terraced house
    • Bungalow
    • Flat
    • Other
  • Age of the propertyChoose one
    • Before 1919
    • 1919 to 1944
    • 1945 to 1979
    • 1980 to 1999
    • 2000 or later
    • Not known
  • BedroomsNumber
  • People living thereNumber
  • Current heating*Choose one
    • Mains gas
    • Oil
    • LPG
    • Electric
    • Solid fuel
    • Other
  • GuidanceBoiler Upgrade Scheme (England and Wales). £7,500 towards an air source or ground source heat pump replacing fossil fuel heating, for the owner of the property, with an MCS certified installer applying on their behalf. Until March 2027 there is an extra £1,500 if the property is heated by oil or LPG and has no mains gas connection. Hybrid systems are not covered.
  • EPC rating, if knownShort answer

Insulation and fabric

  • Main wall typeChoose one
    • Cavity, filled
    • Cavity, unfilled
    • Solid
    • Timber frame
    • System built
    • Not known
  • Loft insulation depth (mm)Number
  • GlazingChoose one
    • Single
    • Double
    • Triple
    • Mixed
  • Ground floorChoose one
    • Solid
    • Suspended timber
    • Not known
  • Draughts, damp or other things that affect heat lossNotes

Rooms

  • GuidanceMCS installers design heat pumps to MIS 3005-D, the MCS heat pump design standard. It calls for a heat load calculation to BS EN 12831-1 using internal design temperatures no lower than its table (for example living room 21°C, bedroom and kitchen 18°C, bathroom 22°C), and the installer is given the heat loss of each room. Measure every heated room here. This form records the inputs; it does not calculate the heat loss.
  • Rooms
    Repeat for each room. Each one asks:
    • Room*Short answer
    • Length (m)*Number

      Measuring from a photo gives an estimate. Use a tape for the final figure.

    • Width (m)*Number

      Measuring from a photo gives an estimate. Use a tape for the final figure.

    • Ceiling height (m)*Number

      Tape or laser, or measure from a photo of a wall taken square on, with a door as the reference.

    • Floor area (m²)Worked out by the form
      Shown only when the answers above make it relevant
    • Volume (m³)Worked out by the form
      Shown only when the answers above make it relevant
    • Design temperature (°C)Number
    • Number of external wallsNumber
    • Window and door glazing area (m²)Number
    • Heat emitterChoose one
      • Radiator
      • Underfloor heating
      • Fan coil
      • None
    • Emitters in this room
      Repeat for each emitter. Each one asks:
      Shown only when the answers above make it relevant
      • TypeChoose one
        • Single panel radiator
        • Double panel radiator
        • Triple panel radiator
        • Column radiator
        • Underfloor loop
        • Fan coil
        • Other
      • Width (mm)Number

        Measuring from a photo gives an estimate.

      • Height (mm)Number
      • Rated output (W at the stated delta T)Number
      • Delta T for that rating (°C)Number
    • Room heat loss from your calculation (W)Number

      Optional. Fill in once the room-by-room calculation is done in your design software. The form adds the rooms up; it does not calculate heat loss.

    • Heat loss per m² of floor (W/m²)Worked out by the form
      Shown only when the answers above make it relevant
    • PhotosPhotos
  • Total heated floor area (m²)Worked out by the form
  • Heated roomsWorked out by the form
  • Total heated volume (m³)Worked out by the form
  • Total glazing area (m²)Worked out by the form
  • Glazing as a share of the floor area (%)Worked out by the form
    Shown only when the answers above make it relevant
  • Total of the room heat losses entered (W)Worked out by the form
    Shown only when the answers above make it relevant

Outdoor unit

  • Proposed outdoor unit position*Notes
  • Outdoor unit positionShort answer

    Stand where the unit would go and mark it, so the installer and the noise check use the same spot.

  • Distance from the nearest boundary (m)Number
  • Clear space in front of the unit position (m)Number

    Measuring from a photo gives an estimate. Use a tape for the final figure.

  • Clear space to the side (m)Number

    Measuring from a photo gives an estimate. Use a tape for the final figure.

  • Manufacturer's minimum in front (m)Number

    From the installation manual of the unit you plan to fit.

  • Manufacturer's minimum to the side (m)Number
  • Clearance checkWorked out by the form
    Shown only when the answers above make it relevant
  • Base, drainage for condensate and pipe route to the houseNotes
  • Are there neighbouring windows or gardens close to the unit position?Yes or No
  • Distance to the nearest neighbouring door or window of a habitable room (m)Number

    For the noise check under MCS 020(a), done by the installer. The form does not calculate noise levels.

    Shown when “Are there neighbouring windows or gardens close to the unit position?” is Yes
  • Photos of the outdoor unit positionPhotos

Hot water, electrics and customer

  • Existing hot water cylinder size and location, if anyShort answer
  • Space for a new cylinderNotes
  • Main fuse ratingChoose one
    • 60 A
    • 63 A
    • 80 A
    • 100 A
    • Not marked
  • Earthing arrangementChoose one
    • TN-C-S (PME)
    • TN-S
    • TT
    • Not determined
  • Photos of the meter and consumer unitPhotos
  • Walk Cam: heat pump survey walk-roundWalk Cam video with voice-to-text

    Optional. Film a guided walk-through on the SiteSurvey app; each clip keeps its spoken note.

  • What the customer wants (comfort, running costs, timescale)Notes

Actions and sign-off

  • Are further actions needed?Yes or No
  • Further actions
    Repeat for each action. Each one asks:
    Shown when “Are further actions needed?” is Yes
    • What needs doing?*Notes
    • PriorityChoose one
      • Urgent
      • High
      • Medium
      • Low
    • Who will do it?Short answer
    • Due dateDate
    • StatusChoose one
      • Open
      • In progress
      • Completed
  • Inspector nameWorked out by the form
  • Position or company of the surveyorShort answer
  • Inspector signatureSignature
  • CheckSigning records what was found on the day. It is not a guarantee of condition and does not replace any examination, test, design check or repair needed from a competent person.

See it filled in

A completed heat pump survey report, made by SiteSurvey from a fictional site visit: every answer, the photos, the guidance that applied and the sign-off, ready to send as a PDF.

See completed form (PDF) ↗

Heat pump survey FAQs

Is there a grant for a heat pump?

In England and Wales the Boiler Upgrade Scheme gives property owners £7,500 towards an air source or ground source heat pump that replaces fossil fuel heating. Until March 2027 there is an extra £1,500 if the property is heated by oil or LPG and has no mains gas connection. An MCS certified installer applies on the owner's behalf.

Does the form calculate the heat loss?

No. MCS installers design heat pumps to MIS 3005-D, the MCS heat pump design standard, which calls for a heat load calculation to BS EN 12831-1 with internal design temperatures no lower than its table, such as 21°C for a living room and 18°C for a bedroom. This form records the measurements and details the calculation needs, and works out each room's floor area and volume and the totals. Once you have done the calculation in your design software you can enter each room's heat loss, and the form adds them up and shows watts per square metre for each room.

What is measured in each room?

Length, width and ceiling height, the design temperature, the number of external walls, the window and door glazing area, and the heat emitter, with the size and type of each radiator. Each room becomes its own space in the SiteSurvey project, with photos.

What about insulation?

The form records the main wall type, such as filled or unfilled cavity or solid, the loft insulation depth, glazing and ground floor type, with notes on draughts and damp. GOV.UK says you are still eligible for the grant if you have already had funding for insulation.

Where can the outdoor unit go?

The form records the proposed position with a GPS pin, the distance to the nearest boundary, the clear space in front and to the side against the minimums in the unit's manual, the base, condensate drainage and pipe route, and the distance to the nearest neighbouring window for the MCS 020(a) noise check, which the installer does. Planning rules for outdoor units vary, so the installer checks the position before the design is finalised.

Who uses this survey?

Heating engineers and MCS certified heat pump installers surveying homes for air source or ground source heat pumps, and retrofit assessors collecting heating details.