Skip to main content

Form library · Facilities and maintenance

PAT testing sheet and record template

A PAT testing sheet for portable appliance inspection and test records. List each appliance with its ID, location and class, record the visual inspection and any test readings, mark it pass or fail and say what was done with a failure. The form counts passes and fails, and the customer signs on the device. Every question is listed below, and you can fill the live form in on this page.

Ready to use from the form library, and every question is yours to edit. Try it for a small trial fee, cancel any time.

Try it on your phone

Try it on this phone

Fill in the PAT testing record on your phone now

See how the PAT testing record looks on your phone

Scan the code with your phone camera. It opens the real form, no sign-up needed.

Open the live example and fill it in, just as your team would on site. No sign-up needed.

See it on this phone

Every question is editable. Add this form to your account, then change the wording, add or remove questions and options, and make it fit your own jobs.

Or start your trial with this form ready →

One email, and we won't add you to a mailing list.

What should a PAT testing record include?

A PAT testing sheet records each appliance identifier, location and class, the visual inspection, any tests performed and readings, the result and follow-up action. This PAT testing record template keeps those appliance rows together with the person carrying out the work, instrument details and sign-off.

Last updated . Facts checked by the SiteSurvey team on 5 October 2026 against HSE portable appliance testing FAQs, HSE INDG236, Maintaining portable electric equipment in low-risk environments and regulation 4 of the Electricity at Work Regulations 1989.

How to make this record useful

Appliance result and follow-up action

Appliance A-018, office kettle, first-floor kitchen: visual inspection records damage to the cable near the plug. Result and action are entered against A-018, with a photo reference and a note that the site contact was informed. No electrical test readings are invented to complete empty boxes.

Fictional example. Record the actual evidence and approved arrangements for your job.

A common recording mistake

A certificate heading or a total number of passes does not replace the individual appliance records. Distinguish checks that were carried out from those that were not, and keep any failed item identifiable.

What happens next

Review the sheet for missing identifiers and unresolved actions before sharing it. Keep the appliance-level evidence with the summary, and record subsequent work or rechecks as dated entries.

Built for testing appliances room by room

Work through the building one room at a time. Each appliance gets its class, checks, readings, result and retest interval, and the form counts what passed, what failed, what came out of use and what is due again within a year.

PAT totals on a phone: appliances checked 11, passed 8, failed 3 and a pass rate of 73 percent

Pass and fail counted for you

Every room counts its own appliances, passes and fails, and the record totals them with a pass rate. Failed items are split into those taken out of use and any left in use, which brings up a red warning.

How calculated fields work →
An appliance on a phone: result Fail, action Repaired and retested: pass, and a retest interval of 12 months

Retest intervals that fit the use

Choose a retest interval for each item: shorter for leads and lights that move around or go out on site, longer for office IT. The form counts the items due again within 12 months, so the next visit is planned.

How calculated fields work →
A four-way extension lead on an office carpet with its outer sheath split near the plug, showing the inner wires

A photo of every defect

Damaged cables, cracked casings and wrong fuses are photographed with the appliance they belong to and printed beside it in the report.

The test, on camera

Film the tested items with Walk Cam and say the ID and result as you go, for a record of what was on site that day.

How Walk Cam works →

A completed PAT testing record

Eleven appliances in three rooms at a fictional studio. A kettle and a studio extension lead failed on visual inspection and came out of use, and a desk fan had the wrong fuse, now replaced.

A kettle lead with its sheath pulled out of the plug, showing the coloured inner wires
KS-0101 kettle · damaged cable · removed from use
A four-way extension lead with a split sheath near the plug
KS-0142 studio lead · split sheath · removed from use

Try the PAT testing record form live

Answer a few questions and watch it adapt. Your answers are not saved, and any photos you add are deleted within the hour.

Live form: PAT Testing RecordOpen full screen ↗
Fill it in right here

This is the real form as your team would use it: questions appear as you answer, scores work themselves out and you can add photos and signatures. No sign-up needed. Or open a completed example to see every answer, photo and score filled in.

Want to see one filled in? See a completed PAT testing record report (PDF), made by SiteSurvey from a fictional site visit.

For teams

Using the PAT testing record template for client work?

Paper or a spreadsheet works for the odd job. When your team does this every week, SiteSurvey keeps every visit in one place and turns each one into a report you can send.

  • Everyone fills in the same form on their phone, with photos attached to the answer they belong to.
  • Each visit becomes a branded PDF report for the client, with no retyping.
  • Every site, visit and report is kept together in one account, not scattered across email and shared drives.

Fill it in on a phone or tablet

Your team completes the pat testing record on site in the SiteSurvey app on iPhone, iPad and Android phones and tablets. The project name and address fill in for them, it works without signal, and it syncs when the device is back online with photos kept against the question they answer.

Customers and subcontractors do not need the app: send them a link and they can fill it in from any browser.

The PAT Testing Record form in the SiteSurvey app on a tablet
The PAT Testing Record form in the SiteSurvey app on a phone

Every question in the PAT testing record template

Portable appliance inspection and test record: each appliance with its ID, location, class, visual checks, test readings, pass or fail and the action taken. 3 sections and 52 questions. Follow-up questions and guidance appear only when an answer calls for them, so the person on site never sees the ones that do not apply.

Make it your own: every question is editable

This is a starting point, not a fixed form. Once it is in your SiteSurvey account you can reword any question, add or remove questions, sections and answer options, and add your own logo, so it fits the way your team works and the jobs you do.

Details you only enter once

Add this form to a project in SiteSurvey and it fills in what the project already knows, so nobody on site retypes it and every form on the job uses the same names. Anything filled in can still be changed.

  • Project: the project name
  • Customer: the project's customer
  • Site: the site, when the form is opened for a space or a product
  • Site address: the site address, from the space or the project

Job details

Who tested, with what, and where.

  • ProjectShort answer

    Filled in from the project in SiteSurvey.

    Fills in from the project name
  • CustomerShort answer
    Fills in from the project's customer
  • Site*Short answer
    Fills in from the site, when the form is opened for a space or a product
  • Site addressShort answer
    Fills in from the site address, from the space or the project
  • Date*Date
  • Inspected and tested byShort answer
  • Test instrument make and modelShort answer
  • Serial numberShort answer
  • Calibration dateDate
  • Areas coveredShort answer

    Note any rooms or equipment you could not get to.

  • GuidanceWhat the law asks for. HSE says the law does not make inspection or testing of electrical appliances a legal requirement, nor require it every year. Equipment must be maintained so it is safe, and how often it is checked depends on the type of equipment and where it is used. There is no legal requirement to label equipment or keep records, but HSE says both can be a useful management tool. Sources: The Electricity at Work Regulations 1989, regulation 4(2), require electrical systems to be maintained so as to prevent danger, so far as reasonably practicable. The IET Code of Practice for In-service Inspection and Testing of Electrical Equipment (5th edition) sets out how to inspect and test, and suggests intervals.

Appliances

One entry for each appliance. Unplug it and look before you test.

  • Rooms and areas
    Repeat for each entry. Each one asks:
    • Room or area*Short answer
    • Appliances in this room
      Repeat for each appliance. Each one asks:
      • Appliance IDShort answer
      • Scan the appliance ID labelScan a label: appliance id, serial number

        Optional. Scan the label or tag to capture its numbers.

      • Description*Short answer
      • ClassChoose one
        • Class I: earthed
        • Class II: double insulated
        • Lead or extension only
      • Check carried outChoose one
        • Visual inspection only
        • Visual inspection and test
      • Visual inspection*Choose one
        • Pass
        • Fail
      • What is wrong?Tick all that apply
        • Damaged cable
        • Damaged plug
        • Wrong fuse
        • Cable not gripped in the plug
        • Cracked or damaged casing
        • Signs of overheating
        • Taped or non-standard joint
        • Wet or contaminated
        • Other (describe)
        Shown when “Visual inspection” is “Fail”
      • Fuse fitted (A)Number
      • Earth continuity (ohms)Number
        Shown only when the answers above make it relevant
      • Insulation resistance (megohms)Number
        Shown only when the answers above make it relevant
      • Polarity and wiring correct?Choose one
        • Correct
        • Incorrect
        • Not applicable
        Shown only when the answers above make it relevant
      • Functional checkChoose one
        • Pass
        • Fail
        • Not done
      • Result*Choose one
        • Pass
        • Fail
      • Action takenChoose one
        • Removed from use and labelled
        • Repaired and retested: pass
        • Disposed of
        • Left in use: customer informed
        Shown when “Result” is “Fail”
      • Retest intervalChoose one

        Base it on how the item is used: kit that moves about, is hired out or used on site needs checking more often than office IT.

        • 3 months
        • 6 months
        • 12 months
        • 24 months
        • 48 months
        Shown only when the answers above make it relevant
      • WarningA failed appliance has been left in use. The person told is recorded below.
        Shown when “Action taken” is “Left in use: customer informed”
      • Suggested next checkDate
      • Photos of defectsPhotos
    • This room: appliances checkedWorked out by the form
    • This room: passedWorked out by the form
    • This room: failedWorked out by the form
    • This room: failed and taken out of useWorked out by the form
    • This room: failed but left in useWorked out by the form
    • This room: due again within 12 monthsWorked out by the form
  • Appliances checkedWorked out by the form
  • PassedWorked out by the form
  • FailedWorked out by the form
  • Pass rate (%)Worked out by the form
    Shown only when the answers above make it relevant
  • Failed and taken out of useWorked out by the form
  • Failed but left in useWorked out by the form
  • Due again within 12 monthsWorked out by the form

    Items with a retest interval of 12 months or less.

  • WarningA failed appliance has been left in use. Record who was told and why on the summary page, and make sure it is not used until it is repaired and retested.
    Shown only when the answers above make it relevant

Summary and sign-off

What the customer needs to know.

  • Have all failed appliances been taken out of use?Yes or No
  • Who was told about the failed appliances?Short answer
  • RecommendationsNotes

    For example more frequent checks for equipment that is moved a lot or used in harsh conditions.

  • GuidanceHSE says the person doing the testing needs to be competent to do it. In many low-risk environments a sensible member of staff can do the visual inspections if they have enough knowledge and training.
  • Is the customer or their representative available to sign?Yes or No
  • Why not, and who will you send the report to?Short answer
    Shown when “Is the customer or their representative available to sign?” is No
  • Customer nameShort answer
    Shown when “Is the customer or their representative available to sign?” is Yes
  • PositionShort answer
    Shown when “Is the customer or their representative available to sign?” is Yes
  • Customer commentNotes
    Shown when “Is the customer or their representative available to sign?” is Yes
  • Customer signatureSignature
    Shown when “Is the customer or their representative available to sign?” is Yes
  • Tester nameWorked out by the form
  • Tester signatureSignature

See it filled in

A completed PAT testing record report, made by SiteSurvey from a fictional site visit: every answer, the photos, the guidance that applied and the sign-off, ready to send as a PDF.

See completed form (PDF) ↗

PAT testing record FAQs

Is PAT testing a legal requirement?

HSE says the law does not make inspection or testing of electrical appliances a legal requirement, nor require it every year. Regulation 4 of the Electricity at Work Regulations 1989 requires electrical systems to be maintained, as far as necessary, to prevent danger, and HSE says how often equipment is checked depends on its type and where it is used.

Do I have to keep PAT records or label appliances?

HSE says there is no legal requirement to label equipment that has been inspected or tested, nor to keep records, but that a record and labelling can be a useful management tool. This form is that record, with a suggested next check date for each appliance.

Who can do PAT testing?

HSE says the person doing the testing needs to be competent to do it. In many low-risk environments a sensible member of staff can do the visual inspections if they have enough knowledge and training. The form records whether each appliance had a visual inspection only or an inspection and test.

Is PAT testing the same as test and tag?

Broadly, yes. Test and tag is the Australian and New Zealand name for inspecting and testing portable electrical equipment and fixing a tag that shows when it was last tested, under AS/NZS 3760. PAT testing is the UK name. The record of each appliance, its visual inspection and its test results works the same way, but test and tag follows AS/NZS 3760 for its tests and retest intervals rather than UK guidance.

What is recorded for each appliance?

The ID, description, location and class (earthed, double insulated, or a lead or extension), the visual inspection result with what is wrong on a failure, the fuse fitted, earth continuity and insulation resistance where tested, polarity for leads, a functional check, the result and photos of defects. The form does not set pass limits: use the ones in the guidance you test to.

What happens when an appliance fails?

The action is recorded as removed from use and labelled, repaired and retested, disposed of, or left in use with the customer informed. Left in use shows a warning, and the summary page asks whether all failed appliances are out of use and who was told.

How many appliances fit on one record?

Up to 250. The form counts the appliances checked, passed and failed. In the SiteSurvey app it works offline, and the record goes out as a PDF or a share link.

Related

Use this PAT testing record form with your team

Add it from the form library in one click, change any question, and every completed form becomes a branded PDF report.

Start your trial →