ProjectShort answer
Filled in from the project in SiteSurvey.
Fills in from the project name
CustomerShort answer
Fills in from the project's customer
Premises*Short answer
Fills in from the site, when the form is opened for a space or a product
AddressShort answer
Fills in from the site address, from the space or the project
Main entrance locationShort answer
Mark it on site, so the record shows which building was assessed on an estate or a site with several blocks.
Date of assessment*Date
Date of the previous assessmentDate
Responsible person*Short answer
The employer, owner, landlord or anyone else with control of the premises.
Other responsible persons for these premisesNotes
For example the landlord or other occupiers: their UK address for notices, and the part of the premises each controls.
Assessor name*Short answer
Assessor organisationShort answer
- GuidanceWhat must be recorded. Since 1 October 2023 every responsible person must record the fire risk assessment in full, including all the findings, and their fire safety arrangements. Where someone is engaged to help with the assessment, their name and organisation must be recorded too. This applies to non-domestic premises and the non-domestic parts of blocks of flats, such as corridors, stairways and plant rooms.
- GuidanceThis form follows the Regulatory Reform (Fire Safety) Order 2005, which applies in England and Wales. Scotland and Northern Ireland have their own fire safety law.
What is the building used for?Choose one
Number of flatsNumber
Height of the top storey floor above ground (m)Number
From the lowest ground next to the building to the floor of the top storey. From a photo of the elevation it is an estimate: where it is close to 11 m or 18 m, check the drawings.
Height band for the 2022 regulationsWorked out by the form
Shown only when the answers above make it relevant
- GuidanceFire Safety (England) Regulations 2022. In any block with two or more flats, the responsible person must give residents fire safety instructions and information about the importance of fire doors. These regulations apply in England.
- GuidanceTop storey above 11 m. The fire doors in the common parts must be checked at least every 3 months, and flat entrance doors at least every 12 months on a best endeavours basis, with a record of the steps taken where access was not given.
Shown only when the answers above make it relevant
- Guidance18 m or 7 storeys or more. The regulations add a secure information box, wayfinding signs for firefighters, building plans and information about the external walls for the fire and rescue service, and monthly checks of lifts for firefighters and of essential firefighting equipment.
Shown only when the answers above make it relevant
Have residents been given fire safety instructions and fire door information in the last 12 months?Yes or No
Are the communal and flat entrance fire door checks up to date?Yes or No
Shown only when the answers above make it relevant
Is there a secure information box with the building plans and a responsible person contact?Yes or No
Shown only when the answers above make it relevant
Are floor and flat numbers signed for firefighters?Yes or No
Shown only when the answers above make it relevant
Are lifts for firefighters and essential firefighting equipment checked every month?Yes or No
Shown only when the answers above make it relevant
- CheckFire Safety Act 2021. In force in England since 16 May 2022. In a building with two or more sets of domestic premises, the Fire Safety Order applies to the building structure, the external walls and anything attached to them (including cladding, windows and balconies) and to all doors between the flats and the common parts, including flat entrance doors. The assessment must cover them.
Does this assessment cover the external walls, including cladding, windows and balconies?Yes or No
Does it cover the flat entrance doors?Yes or No
External wall construction, cladding and balconies: what you found and any specialist assessment (for example a PAS 9980 appraisal) referred toNotes
- WarningAssessment incomplete. The Fire Safety Act 2021 requires the external walls and flat entrance doors of this building to be covered by the fire risk assessment. Record how and when they will be assessed as an action.
Shown only when the answers above make it relevant
Photos of the building elevationPhotos
Number of floorsNumber
Most people in the building at one timeNumber
Does anyone sleep on the premises?Yes or No
Brief description of the building and how it is usedNotes