Skip to main content

Form library · AV and IT

AV maintenance checklist

For AV engineers maintaining meeting rooms, classrooms and halls. Test each room the way a user would, and the form counts the checks with a fault, the defects fixed on the visit and the urgent ones still open. It compares projector lamp hours with the rated life and flags a rack running above 27 °C. Try the form below, see every question or open a completed example.

Ready to use from the form library, and every question is yours to edit. Try it for a small trial fee, cancel any time.

Try it on your phone

Try it on this phone

Fill in the AV maintenance on your phone now

See how the AV maintenance looks on your phone

Scan the code with your phone camera. It opens the real form, no sign-up needed.

Open the live example and fill it in, just as your team would on site. No sign-up needed.

See it on this phone

Every question is editable. Add this form to your account, then change the wording, add or remove questions and options, and make it fit your own jobs.

Or start your trial with this form ready →

One email, and we won't add you to a mailing list.

What should an AV maintenance checklist include?

An AV maintenance checklist should test each room from cold: the display or projector, every input, speakers, microphones, the hearing loop, a test video call, the camera and the control system. It should record projector lamp or laser hours and filter cleaning, firmware, cleaning of screens and vents, defects with a priority, and how each room was left. Racks and central equipment should be checked too.

Last updated . Facts checked by the SiteSurvey team on 5 October 2026 against regulation 4 of the Electricity at Work Regulations 1989 and HSE portable appliance testing FAQs.

Built for planned AV maintenance visits

Test each room the way a user would, with the form on a phone. The form counts the checks with a fault in each room and across the visit, the defects fixed on the day and the urgent ones still open, and compares projector lamp hours with the rated life so the lamp is ordered before it fails.

Lamp hours 3420 against a rated life of 3600 hours, worked out as 95% of the rated life used, with an amber note to order a replacement lamp

Lamp hours against the rated life

Enter the lamp or laser hours from the projector menu and the rated life from the maker. Over 90% shows an amber note, so the customer can budget for the lamp before the picture goes dim in the middle of an assembly.

How calculated fields work →
1 check with a fault in this room, worked out from the room's display, audio, hearing loop, video call, camera, control and cable checks

Faults counted in each room

Each room counts the checks that found a fault: picture, speakers, microphones, hearing loop, test call, camera, control and cables. A room with three faults stands out from one with a loose cable.

How calculated fields work →
Counts worked out as 3 rooms checked, 2 with a defect, 0 out of use, 67% left fully working, 2 checks with a fault, 1 defect fixed on this visit, 0 urgent defects still open and 1 projector over 90% of rated life

The visit summed up

The form adds the rooms up: the share left fully working, checks with a fault, defects fixed on the visit, urgent defects still open with a red note, projectors near the end of their lamp life and firmware updates outstanding.

How calculated fields work →

A completed AV maintenance visit

A fictional academy's termly visit: three rooms, a crackling hall speaker to replace within a month, a bent HDMI cable replaced on the day, and the hall projector at 3,420 of its rated 3,600 lamp hours. Open it as a filled-in form, or switch to a blank copy and try it yourself.

A school hall with a ceiling-mounted projector on a pole and a screen above the stage
Main hall projector · 95% of rated lamp life
A round ceiling speaker in a hall ceiling
Hall speaker 3 · crackles · replace by 16 Oct
Up to the hall projector and its screen

Try the AV maintenance form live

Answer a few questions and watch it adapt. Your answers are not saved, and any photos you add are deleted within the hour.

Live form: AV Maintenance VisitOpen full screen ↗
Fill it in right here

This is the real form as your team would use it: questions appear as you answer, scores work themselves out and you can add photos and signatures. No sign-up needed. Or open a completed example to see every answer, photo and score filled in.

Want to see one filled in? See a completed AV maintenance report (PDF), made by SiteSurvey from a fictional site visit.

Fill it in on a phone or tablet

Your team completes the av maintenance visit on site in the SiteSurvey app on iPhone, iPad and Android phones and tablets. The project name and address fill in for them, it works without signal, and it syncs when the device is back online with photos kept against the question they answer.

Customers and subcontractors do not need the app: send them a link and they can fill it in from any browser.

The AV Maintenance Visit form in the SiteSurvey app on a tablet
The AV Maintenance Visit form in the SiteSurvey app on a phone

Every question in the AV maintenance template

Preventive maintenance for meeting room and classroom AV: room by room display, audio, video call and control checks, defects and sign-off. 6 sections and 73 questions. Follow-up questions and guidance appear only when an answer calls for them, so the person on site never sees the ones that do not apply.

Make it your own: every question is editable

This is a starting point, not a fixed form. Once it is in your SiteSurvey account you can reword any question, add or remove questions, sections and answer options, and add your own logo, so it fits the way your team works and the jobs you do.

Details you only enter once

Add this form to a project in SiteSurvey and it fills in what the project already knows, so nobody on site retypes it and every form on the job uses the same names. Anything filled in can still be changed.

  • Project: the project name
  • Customer: the project's customer
  • Site: the site, when the form is opened for a space or a product
  • Address: the site address, from the space or the project

Job details

The job and the site.

  • ProjectShort answer

    Filled in from the project in SiteSurvey.

    Fills in from the project name
  • Job or contract referenceShort answer
  • CustomerShort answer
    Fills in from the project's customer
  • Site*Short answer
    Fills in from the site, when the form is opened for a space or a product
  • AddressShort answer
    Fills in from the site address, from the space or the project
  • Date of visit*Date
  • Type of visit*Choose one
    • Planned maintenance
    • Call-out for a fault
    • Return visit
  • What was reported, and by whom?Notes
    Shown when “Type of visit” is “Call-out for a fault”
  • Reference of the earlier jobShort answer
    Shown when “Type of visit” is “Return visit”
  • Engineer nameShort answer

Room by room

One entry for each room or system. Test it the way a user would.

  • GuidanceStart every room from cold: switch it on from the touch panel or remote, share a laptop, and make a test call if the room has video conferencing. Faults that users report rarely show on equipment that is already on.
  • Rooms checked
    Repeat for each room. Each one asks:
    • Room*Short answer
    • Type of roomChoose one
      • Meeting room
      • Boardroom
      • Classroom
      • Lecture theatre
      • Hall or auditorium
      • Reception or signage
      • Other (describe)
    • DisplayChoose one
      • Flat panel
      • Interactive panel
      • Projector
      • LED or video wall
      • None
    • PictureChoose one
      • OK
      • Defect
      Shown only when the answers above make it relevant
    • Lamp or laser hoursNumber
      Shown when “Display” is “Projector”
    • Rated lamp or laser life (hours)Number

      From the maker's data sheet or the projector menu.

      Shown when “Display” is “Projector”
    • Rated life used (%)Worked out by the form
      Shown only when the answers above make it relevant
    • CheckOver 90% of the rated life. Order a replacement lamp, or quote for one, before it fails.
      Shown only when the answers above make it relevant
    • Filter cleaned or replaced?Yes or No
      Shown when “Display” is “Projector”
    • Image fills the screen and is in focus?Yes or No
      Shown when “Display” is “Projector”
    • Inputs testedTick all that apply
      • HDMI
      • USB-C
      • Wireless presentation
      • Room PC
      • Document camera
      • Other (describe)
    • SpeakersChoose one
      • OK
      • Defect
      • Not fitted
    • MicrophonesChoose one
      • OK
      • Defect
      • Not fitted
    • Hearing loopChoose one
      • Working
      • Not working
      • Not tested
      • Not fitted
    • Video callChoose one
      • Test call OK
      • Fault on test call
      • Not tested
      • Not fitted
    • CameraChoose one
      • OK
      • Defect
      • Not fitted
    • Touch panel or control systemChoose one
      • OK
      • Defect
      • Not fitted
    • Table and wall plates, cables and adaptersChoose one
      • OK
      • Defect or missing
    • Firmware and softwareChoose one
      • Up to date
      • Updated on this visit
      • Update outstanding
      • Not checked
    • Screens, lenses and vents cleaned?Yes or No
    • Checks with a fault in this roomWorked out by the form
    • Any defect in this room?Yes or No
    • Describe the defect and what you didNotes
      Shown when “Any defect in this room?” is Yes
    • Fixed and tested on this visit?Yes or No
      Shown when “Any defect in this room?” is Yes
    • PriorityChoose one
      • Urgent: stops the system being used
      • Soon: within a month
      • Routine: at the next visit
      Shown when “Any defect in this room?” is Yes and “Fixed and tested on this visit?” is No
    • Who will fix it?Short answer
      Shown when “Any defect in this room?” is Yes and “Fixed and tested on this visit?” is No
    • By when?Date
      Shown when “Any defect in this room?” is Yes and “Fixed and tested on this visit?” is No
    • PhotosPhotos
      Shown when “Any defect in this room?” is Yes
    • How was the room left?*Choose one
      • Fully working
      • Working with a defect
      • Out of use
  • Rooms checkedWorked out by the form
  • Rooms with a defectWorked out by the form
  • Rooms out of useWorked out by the form
  • Rooms left fully working (%)Worked out by the form
    Shown only when the answers above make it relevant
  • Checks with a faultWorked out by the form
  • Defects fixed on this visitWorked out by the form
  • Urgent defects still openWorked out by the form
  • Projectors over 90% of rated lifeWorked out by the form
  • Rooms with a firmware update outstandingWorked out by the form
  • WarningAn urgent defect is still open. Tell the customer which room cannot be used, and record who will fix it and when.
    Shown only when the answers above make it relevant

Racks and central equipment

Equipment that serves more than one room.

  • Is there a rack or central equipment?Yes or No
  • Rack fans and ventilationChoose one
    • Working
    • Defect
    • None fitted
    Shown when “Is there a rack or central equipment?” is Yes
  • Temperature at the front of the rack (°C)Number
    Shown when “Is there a rack or central equipment?” is Yes
  • CheckAbove 27 °C at the front of the rack, the top of the ASHRAE recommended range for air going into IT equipment. Check the room cooling, the fans and anything blocking the airflow.
    Shown only when the answers above make it relevant
  • Matrix, audio processor and amplifiersChoose one
    • OK
    • Defect
    Shown when “Is there a rack or central equipment?” is Yes
  • AV network switchesChoose one
    • OK
    • Defect
    • None
    Shown when “Is there a rack or central equipment?” is Yes
  • Did you take a backup of the control and audio configuration?Yes or No
    Shown when “Is there a rack or central equipment?” is Yes
  • NotesNotes
    Shown when “Is there a rack or central equipment?” is Yes

Mains leads and plugs

A visual check of what users plug in and unplug.

  • Did you look over the mains leads, plugs and extension leads?Yes or No
  • Any damaged leads, plugs or overloaded extensions?Yes or No
    Shown when “Did you look over the mains leads, plugs and extension leads?” is Yes
  • What, where, and what did you do?Notes
    Shown when “Any damaged leads, plugs or overloaded extensions?” is Yes
  • GuidancePortable appliance testing. The law requires electrical equipment to be maintained so it is safe (Electricity at Work Regulations 1989). HSE says it does not require testing every year: how often equipment is checked depends on its type and where it is used. Damaged leads are taken out of use.

Outcome and parts

How the system was left and what happens next.

  • Outcome of the visit*Choose one
    • All rooms fully working
    • Working with defects outstanding
    • One or more rooms out of use
  • What needs doing next, and who will do it?Notes
    Shown only when the answers above make it relevant
  • RecommendationsNotes
  • Did you use any parts or materials?Yes or No
  • Parts and materials used
    Repeat for each part. Each one asks:
    Shown when “Did you use any parts or materials?” is Yes
    • ItemShort answer
    • Part numberShort answer
    • QuantityNumber
  • Next visit dueDate

Sign-off

Customer and engineer.

  • Is the customer or their representative available to sign?Yes or No
  • Why not, and who will you send the report to?Short answer
    Shown when “Is the customer or their representative available to sign?” is No
  • Customer nameShort answer
    Shown when “Is the customer or their representative available to sign?” is Yes
  • PositionShort answer
    Shown when “Is the customer or their representative available to sign?” is Yes
  • Customer commentNotes
    Shown when “Is the customer or their representative available to sign?” is Yes
  • Customer signatureSignature
    Shown when “Is the customer or their representative available to sign?” is Yes
  • Engineer nameWorked out by the form
  • Engineer signatureSignature

See it filled in

A completed AV maintenance report, made by SiteSurvey from a fictional site visit: every answer, the photos, the guidance that applied and the sign-off, ready to send as a PDF.

See completed form (PDF) ↗

AV maintenance FAQs

What is checked in each room?

The display or projector picture, the inputs tested (HDMI, USB-C, wireless presentation, room PC, document camera), speakers, microphones, the hearing loop, a test video call, the camera, the touch panel or control system, table and wall plates with their cables and adapters, firmware and cleaning. Each room ends as fully working, working with a defect or out of use.

Does it cover projectors?

Yes. Choosing projector as the display opens the lamp or laser hours and the rated life from the maker, whether the filter was cleaned or replaced, and whether the image fills the screen and is in focus. The form works out the share of the rated life used and flags a lamp over 90%, so the replacement can be ordered before it fails. Flat panels, interactive panels and LED or video walls are covered too.

Why start each room from cold?

The form asks the engineer to switch the room on from the touch panel or remote, share a laptop and make a test call, because faults that users report rarely show on equipment that is already on. That is this form's own advice.

Does AV equipment need PAT testing every year?

No. The Electricity at Work Regulations 1989 require electrical systems to be maintained so as to prevent danger, but HSE says the law does not require testing every year: how often equipment is checked depends on its type and where it is used. The form includes a visual check of mains leads, plugs and extension leads, and records any that were damaged and taken out of use.

Does it cover racks and central equipment?

Yes. It records rack fans and ventilation, the temperature at the front of the rack (with a note above 27 °C, the top of the ASHRAE recommended range for air going into IT equipment), the matrix, audio processor and amplifiers, AV network switches, and whether a backup of the control and audio configuration was taken.

How is the visit reported?

The form counts the rooms checked, rooms with a defect, rooms out of use, the share left fully working, the checks with a fault, defects fixed on the visit, urgent defects still open and projectors near the end of their lamp life, then records the outcome, parts used and the next visit date. The customer signs on the device, or the form records why nobody could. In the SiteSurvey app it works offline, and the report goes out as a PDF or a share link.

Related

Use this AV maintenance form with your team

Add it from the form library in one click, change any question, and every completed form becomes a branded PDF report.

Start your trial →